separating the head from the container. Before doing this operation, disconnect the plug from the power
supply.
• Items 804-805-809-810-815:
Check that the filter bag (28) is correctly inserted inside the aspirator and the filter-ring sticks perfectly to
−
the container (52) to avoid the coming out of the dust. Check that the filter is clean and dry.
Starting from the connector (35), connect in the following order: items 804-805 the outlet sleeve (13), the
−
flexible hose (1), the inlet sleeve (12), the bent extensions (20), the brushes or other tools; items 809-810
the outlet sleeve (13), the flexible hose (1), the inlet sleeve (3), the bent extension (4), the brushes or
other tools; item 815 the flexible hose (22), the tube (24) and the spout (23).
For the different cleaning operations, use the different tools and accessories supplied with the vacuum
−
cleaner.
Attention ! Before connecting the vacuum cleaner to the power supply, check that the supply voltage is the
−
same as that indicated on the specifications plate of the machine.
Insert the pin plug of the vacuum cleaner in a 16A 230v (240v) 50Hz power supply socket and switch on
−
the vacuum cleaner choosing the number of motors according to the cleaning operation to be performed.
The aspirated dust and residues are deposited in the container (52), which can be easily emptied by
−
separating the head and the filter-bag (29) from the container. Before doing this operation, disconnect the
plug from the power supply.
• Item 813:
Check that the filter bag (13) is firmly held in place by the elastic and that the filters are clean and dry.
−
Check that the complementary nylon filter (14) is correctly inserted in the upper part of the aspirator body.
−
Starting from the nozzle (22), connect in the following order : the "Y" connector (23), the flexible tube (21)
−
the outlet sleeve (24) and the electric tool.
Attention ! Before connecting the dust aspirator to the electric tool, check that the voltage of the aspirator
−
is the same as that of the electric tool.
Insert the pin plug of the electric tool in the supplementary socket (27) located on the upper part of the
−
aspirator head.
Attention ! Before connecting the dust aspirator to the power supply, check that the supply voltage is the
−
same as that indicated on the specifications plate of the machine.
Insert the aspirator pin plug in a 16A 230V (240V) 50 Hz power supply socket and place the switch (28) in
−
position "II".
In this mode, each time the electric tool is started the aspirator will also start automatically.
−
The aspirated dust and residues are deposited in the container (15), which can be easily emptied by
−
separating the head and the supplementary nylon filter (14) from the container. Before doing this
operation, disconnect the plug from the power supply.
Thanks to the "Y" connection (23), it is possible to use two electric tools at the same time with the same
−
aspirator.
Placing the switch (28) in position "I" the machine works like a traditional vacuum cleaner.
−
PREPARING THE ASPIRATOR FOR WET VACUUM CLEANING
• Remove the filter bag (items 801-803-813 : pos. 13-14; items 804-805-809-810-815 : pos. 29).
• Connect the accessories following the same procedure as outlined in previous instructions and
connecting the appropriate tool (items 804-805: pos. 17) to the extension tube.
• Attention ! Before connecting the vacuum cleaner to the power supply, check that the supply voltage is the
same as that indicated on the specifications plate of the machine.
• Insert the pin plug of the vacuum cleaner in a 6A 230V (240V) 50Hz power supply socket for items 801-
803 or in a 16A 230v (240V) 50Hz socket for items 804-805-809-810-813-815. Then switch on the
vacuum cleaner (for items 804-805-810-815 switch on the number of motors you need).
• The aspirated liquid is deposited in the container. When it will reach the maximum level, the float (items
801-803-813 : pos. 39; items 804-805-809-810 : pos. 24; items 815 : pos. 48) will block the suction
operation.
• The container can be easily emptied by separating the head from the container. Before doing this operation,
disconnect the plug from the power supply.
6