6.3.2 RP250YDM
▷ Slide the fl ange completely over the suction aperture.
Operating the rotary slide
▷ Turn the red rotary slide inside to position CLOSE to the stop
on the marker ▲.
▷ Place the upper section on the container and close the side
latches.
(* depending on the equipment variant)
6.4 Insert PE emptying and disposal bag*
Only the vacuum cleaners class M and H with special containers
and rotary slider in the suction aperture of types RP250YDM
and RP500YDM are suitable for the use of PE Emptying and
disposal bags.
6.4.1 RP500YDM
Operating the rotary slider*
▶ Push the rotary slider* from the inside to the outside, turn
through 180° (see mark) and then push inwards again from
the outside through the suction spigot
▶ Place the rotary slider* in the suction aperture with the mark ●
pointing upwards.
▷ Slide the fl ange completely over the suction aperture and place
the upper bag opening over the edge of the container.
▷ Place the upper section on the container and close the side
latches.
28 - en
NOTE
NOTE
NOTE
6.4.2 RP250YDM
Operating the rotary slide
▷ Turn the red rotary slide inside to position OPEN to the stop
on the marker ▲.
▷ Slide the fl ange completely over the suction aperture and place
the upper bag opening over the edge of the container.
▷ Place the upper section on the container and close the side
latches.
(* depending on the equipment variant)
7 Changing the fi lter
7.1 Changing the folding fi lter
▷ Shake the folding fi lter cassettes before changing them.
▷ Turn the lock on the latch through 90° in a counter-clockwise
direction with a coin or similar object and push the latch to the
rear.
▷ Fold the hood up
▷ Immediately isolate the folding fi lter cassettes that you have
removed in a dust-tight plastic bag and dispose of properly in
accordance with the stipulations.
▷ Insert new folding fi lter cassettes.
▷ Lift the locking bracket up, fold the hood down and click in place
with light pressure.
8 Changing the motor protection fi lter
If the motor protection fi lter is contaminated this indicates defec-
tive fi lter cassettes.
▷ Replacing the folding fi lter cassettes.
▷ Replace the motor protection fi lter or wash the motor
protection fi lter under fl owing water, dry and re-insert..
NOTE
NOTE