Maintenance and care
Lubricating drive shaft
Angle transmission
Checking the blade
Inspect the drive shaft (A) every 100 hours of use and replenish
grease if it is insufficient.
 Use good quality lithium multi grease.
1.
Remove plug (B) from angle transmission (A).
2.
Add grease, if necessary, using low pressure pump.
 Use good quality lithium multi grease.
 Do not overfill housing.
3.
Reinstall plug.
 Use only blade designated for this model by the manufacturer.
 When a crack is noticed on the blade, do not use it but replace
with a new one.
 Ensure that the blade is correctly fitted in accordance with the
instructions.
 When the cutting blade becomes dull due to wear reverse it for
further use.
 When chip or bend occurs on the blade, vibration will increase.
Replace with new one.
 When filing the blade file 3 cutting edges evenly using a flat file
as shown in the illustration. Otherwise, the balance will be lost
and vibration will increase.
24