THERMOBILE AT 306 Manual Del Usuario página 27

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 56
Fault
The flame goes out
directly after ignition.
AT 300 series
Cause
6
The pump thermostat
has not reached the
right temperature yet.
7
Only for the AT 307:
The hot air thermostat is
defective.
8
Only for the AT 307:
The combustion air fan
is not functioning.
9
There is insufficient sup-
ply of combustion air
10 There is no proper flue
draught.
11
The flue draught is too
high or irregular.
12 The flue draught is too
low.
40.020.933 - rev. 04 - 2011
Solution
Replace the pump thermo-
stat.
Replace the hot air thermo-
stat.
Check the motor and replace
if necessary.
Only for the AT 306:
Clean the holes in the com-
bustion chamber wall, see
fig. 4 (B).
Only for the AT 307:
Clean the holes in the vapor-
iser, see fig. 6 (D).
Only for the AT 307:
Check the functioning of the
combustion air fan.
Check whether the flue is fit-
ted according to the descrip-
tion, see "flue".
Check the flue for leakage.
Clean the flue if necessary.
Position a flue stack valve,
see "flue".
Adjust the flue to the right
draught (see maintenance
table 5.1) with the counter-
weight on the valve(fig.9).
Check all connections in the
flue.
Reduce the number of
bends.
Heighten the flue.
Isolate the flue outside the
building.
Check the flue, see "flue".
English
Action
Dealer
Dealer
Dealer
User
User
Dealer
User
User
User
Dealer
User
User
User
User
User
27

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

At 307

Tabla de contenido