Descargar Imprimir esta página

Medisana 60060 Instrucciones De Manejo página 16

Humidificador uhw

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33
GB
3 Operating / 4 Miscellaneous
3.5
Faults and Fault
Remedying
4 Miscellaneous
4.1
Cleaning and
maintenance
4.2
Disposal
12
• Device will not switch on (LED not illuminating): Plug in the plug; Check power
circuit, socket and fuse.
• No mist (LED lights up red): Fill water tank.
• No mist although tank full: Move rotary knob
surface; Clean atomiser and generator using provided brush and fill tank with
clean water; Rinse device with clean water.
• White deposits: Use clean water or at least 1/2 distilled water / 1/2 fresh tap
water. If a fault cannot be remedied using the described method, please
contact your service centre.
• During everyday use it is advisable to give the device a thorough cleaning at
least every three days. Also clean device before and after long storage periods.
• Before cleaning the device, make sure that it is turned off and the mains plug
is removed from the socket.
• Remove the water tank from the device and empty it.
• Clean the outside of the unit with a soft, damp cloth.
• Please do not use any aggressive substances for cleaning, such as scouring
cream or other detergents, as these may damage the surfaces and reduce the
atomisation effect.
• You can rinse out the water tank with hot water (>65 °C) or an alcohol of at
least 75 % vol. The atomiser chamber should be cleaned using an alcohol-
soaked cloth and cotton bud. Take care to ensure that no water gets inside
the humidifier.
• The ultrasound generator is the most sensitive component in the device. It is
important for it to be kept clean and handled with care. Please use the provi-
ded brush to remove deposits and dirt particles from the outlets. Never clean
the ultrasound generator using metal objects.
• If you do not intend to use the unit for an extended period of time, empty any
remaining water from the tank and dry off the unit.
• Limescale can be removed using a mild descaling agent such as citric acid.
• Store the unit in a cool, dry place, preferably in its original packaging.
• Remove cap from underside of the water tank and store separately to prevent
sleeve gasket from sticking.
This product must not be disposed of together with domestic waste.
All users are obliged to hand in all electrical or electronic devices, regardless
of whether or not they contain toxic substances, at a municipal or commer-
cial collection point so that they can be disposed of in an environmentally
acceptable manner.
Consult your municipal authority or your dealer for information about disposal.
to
; Place device on a level

Publicidad

loading