Power input
ventilation
8. DOUBLE CONNECTOR
ground terminal of the battery using two cables of at least 00 AWG (one for
each negative input of the amplifier).
9. DOUBLE CONNECTOR
power terminal of the battery using two cables of at least 00 AWG (one for
each positive input of the amplifier). Install a 450A fuse/circuit breaker as
close as possible to the battery (recommended no more than 30 cm from
the battery).
For maximum product performance, always use two cables for each
power connection (positive and ground). If desired, power connections
support cables up to 250MCM.
10. REMOTE ACTIVATION (REM):
Use the radio/player remote output for automatic activation of the amplifier
when turning on the radio or use an ON/OFF switch connected to 12V for
manual activation. Make the connection using a cable of at least 18 AWG.
8
9
10
(GROUND):
(POWER):
Responsible for activating the amplifier.
13
ventilation
9
8
Make the connection with the
Make the connection with the