Cut the wires which protrude from the guide by approximately 5 mm, insert the guide in the plug and
crimp the plug with a specifi c tool.
Make sure that the grey sheath remains inside the plug.
This type of connection DOES NOT ensure double insulation.
TECHNICAL SPECIFICATIONS
POWER VOLTAGE AND CONSUMPTION ON TERMINALS V+ V-
Power voltage: ...............................................................................................................................44 ÷ 57 Vdc
Current consumption during video call (*) @48 V: ................................................................................200 mA
Current consumption in standby (*) @48 V: ..........................................................................................140 mA
Working temperature range: .................................................................................................. -10 °C ÷ +50 °C
(*) Current consumption of 30 external name holder tags is included.
Relay contact range C, NC, NO:
Maximum switching voltage: ................................................................................................................ 30 V
Maximum switching current: ...............................................................................................................3,5 A
Maximum switching load: ......................................................................................................... 40 VA 25 W
Max. distance from hall button: .............................................25 m with cable cross-section area 0.5 mm
Max. distance from open door sensor: .................................50 m with cable cross-section area 1.5 mm
Max. distance from supplementary power supply: .............100 m with cable cross-section area 1.5 mm
Max. distance from capacitance lock: ................................100 m with cable cross-section area 1.5 mm
RESTORE DEFAULT SETTINGS
Close the hall button and at the same time press the button on the IP video door unit for 20 seconds. After
20 seconds, the device will beep before restarting, then release both buttons: the previous confi guration of
the IP video door unit will be lost.
DS1060-127
~ 5 mm
1
8
Plug
1
8
2
2
2
2
11