Descaling
For the best water quality, Polar recommend that a
water filter is installed to the mains water supply,
particularly in hard water areas. Doing so will
reduce the build up of limescale and contaminants
in the water tank thus maintaining energy
efficiency and prolonging the life of the appliance.
To de-scale the appliance:
Switch off and disconnect the power supply.
Remove the ice basket and water filter for
cleaning.
Add dilute cleaner into the water tank. (Note:
Choose ice maker specific cleaner and follow
the manufacturer's instructions.)
Clean the water box, evaporator (metal) and
water tank with a soft brush.
Water box
Troubleshooting
A qualified technician must carry out repairs if required.
Fault
The appliance is not
working
Appliance is noisy or
works intermittently
Ice cubes are sticking
together
Compressor runs but no
ice is made
6
CH479_ML_A5_v1_20230419.indb 6
CH479_ML_A5_v1_20230419.indb 6
Note: After descaling, use the first 3 ice
making cycles to flush out the system.
Discard the water and ice created from
these initial cycles.
POLAR recommend this appliance is
descaled monthly or more frequently in
hard water area.
To avoid contamination of ice, please respect
the following instructions:
Evaporator
Probable Cause
The unit is not switched on
Plug or lead is damaged
Fuse in the plug has blown
Mains power supply fault
Power fluctuations
Ice making cycle is too long
Water tank temperature is too low Empty water tank and refill
Refrigerant leak or block in the
refrigerant system
Loosen the drain screw to drain the solution.
Flush out the system thoroughly with clean
water to remove any cleaner residue.
Re-locate all removable parts.
Opening the door for long periods can cause a
significant increase of the temperature in the
compartments of the appliance.
Clean regularly surfaces that can come in
contact with ice and accessible drainage
systems.
Clean water tanks if they have not been used
for 48h.
If the refrigerating appliance is left empty for
long periods, switch off, defrost, clean, dry,
and leave the door open to prevent mould
developing within the appliance.
Solution
Check the unit is plugged in correctly
and switched on
Replace Plug or lead
Replace the fuse
Check mains power supply
Turn off the ice maker and restart after 3
minutes
Reset the ice cube size and restart the
appliance