Information window
During channel selection in the Information window, the following settings can be made or va­
lues displayed.
Display value
Position value, venetian blind
Position value, slat
Restraint
Lock­out protection
Switching cycle counter UP
Total UP operating hours
Operating hours UP
Switching cycle counter DOWN
Total DOWN operating hours
Operating hours DOWN
i The value can be updated using the arrow next to the display values.
6.3 Accesorio
Caja de instalación
eNet server
6.4 Garantía
Reservado el derecho a realizar modificaciones técnicas y formales en el producto, siempre y
cuando sirvan para adaptar el aparato a los avances técnicos.
Prestamos garantía dentro del marco de las disposiciones legales.
Le rogamos envíe el aparato con una descripción del fallo a nuestro servicio central de aten­
ción al cliente.
ALBRECHT JUNG GMBH & CO. KG
Volmestraße 1
58579 Schalksmühle
Telefon: +49.23 55.8 06­0
Telefax: +49.23 55.8 06­2 04
kundencenter@jung.de
www.jung.de
Service Center
Kupferstr. 17­19
44532 Lünen
Germany
82581423
J:0082581423
Explanations
The position value of the Venetian blind can
be changed.
The position value of the slat can be changed.
Display of forced position status.
Display of the lock­out protection status
Display of the switching cycles in the UP direc­
tion with the factor 10, e.g. the value 5 x 10 is
displayed for 50 switching cycles.
Display of the operating hours in the UP direc­
tion since the start of operation.
Display of the operating hours in the UP direc­
tion since the last restart in the Settings win­
dow.
Display of the switching cycles in the DOWN
direction with the factor 10, e.g. the value 5 x
10 is displayed for 50 switching cycles.
Display of the operating hours in the DOWN
direction since the start of operation.
Display of the operating hours in the DOWN
direction since the last restart in the Settings
window.