WARNING:
monoxide exhaust fumes can be lethal in a confined area.
WARNING:
and the unit must be in a stable position when pulling the starter rope (Fig. 14).
WARNING:
animals, windows, automobiles or loose debris.
STARTING INSTRUCTIONS
NOTE: There is no need to turn the unit on. The On/Off switch is in the On ( I ) position at all times (Fig. 3).
Before Starting the Unit
1. Mix gasoline with oil. Refer to Oil and Fuel Mixing Instructions.
2. Fill the fuel tank. Refer to Fueling the Unit.
Starting the Unit
1. Slowly press and release the primer bulb 10 times (Fig. 4). If fuel cannot be seen in the primer bulb,
press and release the primer bulb until fuel is visible.
2. Move the choke lever to the START position (Fig. 4).
3. Crouch in the starting position (Fig. 5).
4. Squeeze and hold the throttle control (Fig. 3).
NOTE: Continue to SQUEEZE and HOLD the throttle control for ALL further steps.
5. Pull the starter rope with a controlled and steady motion 5 times (Fig. 5). DO NOT pull the starter
rope more than 5 times.
6. Move the choke lever to the WARM UP position (Fig. 4).
7. Pull the starter rope with a controlled and steady motion 5 to 10 times to start the engine.
8. Allow the engine to warm up for 60 seconds.
9. Move the choke lever to the RUN position (Fig. 4). Allow the engine to warm up for an additional
60 seconds. The unit may be used during this time.
NOTE: The engine is properly warmed up when it accelerates without hesitation.
IF... the engine hesitates, return the choke lever to the WARM UP position and continue the warm-up.
IF... the engine does not start, repeat the starting procedure.
IF... the engine fails to start after a few attempts: Move the choke lever to the RUN position. Squeeze
and hold the throttle control. Pull the starter rope with a controlled and steady motion until the
unit starts.
IF... the engine is already warm: Move the choke lever to the RUN position. Squeeze and hold the
throttle control. Pull the starter rope with a controlled and steady motion until the unit starts.
STARTING AND STOPPING
Operate this unit only in a well-ventilated outdoor area. Carbon
Avoid accidentally starting the unit. To avoid serious injury, the operator
When starting the unit, make sure it is not directed toward people,
16