CONNECT WIRING
HEAT
BLACK to RED
(Heat)
WHITE to WHITE
WIRING PLATE
GROUND
FROM VENTILATOR
WHITE
to
WHITE
CAUTION
RATING
SPECIFICATIONS
Each two-position rocker
switch is rated 15 A @
120VAC. The total load
120 VAC LINE IN
on this control must not
exceed 20 A @ 120VAC.
L I G H T
S W I T C H
V E N T
S W I T C H
H E A T
S W I T C H
B L K
W H T
L I N E
I N
G R D
G R D
D O U B L E - G A N G S W I T C H B O X
5. Connect electrical wiring.
Run 120 VAC house wiring to installation location. Use
proper UL approved connectors to secure house wiring to
wiring plate. Connect wires as shown in wiring diagram(s).
INSTALL GRILLE & BULB
6. Finish ceiling.
Install ceiling material. Cut out ceiling material closely
around housing.
7. Remove
light lens
from grille.
Insert a small
flat-bladed
screwdriver into
the slot at one
end of the light
lens. Carefully pry
the lens out.
LIGHT
&
FAN
VENTILATOR
HOUSING
RED to BLUE
(Light)
BLACK to BLACK
(Fan)
WHITE to WHITE
BLACK
B L U
R E D
L I G H T
B L K
B L K
V E N T
W H T
B L K
R E D
H E A T
W H T
U N I T
INSTALL GRILLE & BULBS
8. Plug-in
light.
Hold grille
assembly up near
housing. Connect
light plug from
grille assembly to
receptacle inside
of housing.
LIGHT
9. Attach
FAN
grille.
HEAT
Place grille/
reflector
combination
over protruding
screw and
fasten in place
using acorn nut
W H T
provided. HAND
TIGHTEN acorn
W H T
nut 1/4 turn after
it is snug.
W H T
10. Install
bulb.
The unit
accepts a
100-Watt
(maximum)
incandescent
bulb.
11. Attach
light lens.
Hook the tabs
on one end of
the lens into the
slot in the grille.
Lift other end
of lens up and
snap into place.
MODEL 100HL
SCREW
GRILLE
ACoRN NUT
REFLECToR
BoTToM VIEW
Page
LIGHT
USE
THIS
HoLE