READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer at the address or
telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to
prevent backdrafting. Follow the heating equipment manufacturer's
guideline and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American
Society of Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
6. To reduce the risk of fire or electric shock, do not use this range
hood with an additional speed control device.
7. Ducted fans must always be vented to the outdoors.
8. To reduce the risk of fire, use only metal ductwork.
9. Use with approved cord-connection kit only.
10. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1. Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
2. Always turn hood ON when cooking at high heat or when cooking
flaming foods.
3. Clean ventilating fans frequently. Grease should not be allowed to
accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate for the size
of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT
OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal
tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS.
If the flames do not go out immediately, EVACUATE AND CALL
THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN — You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - violent
steam explosion will result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you already
know how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on "Kitchen Fire Safety Tips" published by NFPA.
!
FOR DOMESTIC COOKING ONLY.
!
CAUTION
1. For indoor use only.
2. For general ventilating use only. Do not use to exhaust hazardous
or explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
4. For best capture of cooking impurities, your range hood should be
mounted so that the top of the hood is 24-30" above the cooking
surface.
5. Please read specification label on product for further information
and requirements.
Installer: Leave this manual with
the homeowner.
Homeowner: Operating and
Cleaning information on page 5.
NOTE
If hood is to be installed Non-Ducted:
Purchase a set of (2) non-ducted filters from your
local distributor or retailer and attach them to the
aluminum mesh filters.
TABLE OF CONTENTS
This manual is divided into sections as follows:
"PREPARE HOOD LOCATION"
Run ductwork from roof or wall cap, and electrical wiring from
service panel - to installation location
"PREPARE THE HOOD"
Get your hood ready for installation
"CONNECT WIRING"
Make electrical wiring connections to hood
"INSTALL HOOD"
Secure hood to cabinet and ductwork - install bulbs and filters
"OPERATION"
How to use the hood controls
"CLEANING"
Keep your hood in top working condition
"SERVICE PARTS"
Part numbers and exploded view of hood components
"WARRANTY"
One-year limited warranty and how to contact us
Register your product online at: www.broan.com/register
ALLURE™ QS1 SERIES
RANGE HOOD
Page 1
Patent No.:
US D450, 829 S
!

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Broan ALLURE QS1 Series

  • Página 1 OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:* “INSTALL HOOD” 1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal Secure hood to cabinet and ductwork - install bulbs and filters tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL “OPERATION” THE FIRE DEPARTMENT. How to use the hood controls 2. NEVER PICK UP A FLAMING PAN — You may be burned. “CLEANING” 3. DO NOT USE WATER, including wet dishcloths or towels - violent Keep your hood in top working condition steam explosion will result. 4. Use an extinguisher ONLY if: “SERVICE PARTS” A. You know you have a Class ABC extinguisher and you already Part numbers and exploded view of hood components know how to operate it. B. The fire is small and contained in the area where it started. “WARRANTY” C. The fire department is being called. One-year limited warranty and how to contact us D. You can fight the fire with your back to an exit. * Based on “Kitchen Fire Safety Tips” published by NFPA. Register your product online at: www.broan.com/register...
  • Página 2: Prepare The Hood

    ALLURE™ QS1 SERIES RANGE HOOD Page 2 PREPARE HOOD LOCATION PREPARE HOOD LOCATION ROOF CAP 3¼” X 10” or 7” ROUND 3¼" X 10" 7” ROUND DUCT VERTICAL DUCTING (For vertical (For vertical discharge) discharge) SOFFIT HOUSE WIRING CABINET (Top or Back of hood) WALL CAP HOOD HOOD 24"...
  • Página 3 ALLURE™ QS1 SERIES RANGE HOOD Page 3 PREPARE THE HOOD PREPARE THE HOOD AIR CHUTE Remove Damper/Duct Connector from inside the hood. Set connec- Remove Air tor aside - with Chute - held in mounting screws place with one and parts bag. (1) screw. DAMPER/DUCT NOTE: Be care- CONNECTOR ful not to discon- nect any wires. Remove Wir- ing Cover from inside the hood. Remove Baffle Set cover and from air chute.
  • Página 4: Connect Wiring

    ALLURE™ QS1 SERIES RANGE HOOD Page 4 PREPARE THE HOOD CONNECT WIRING TOP RECTANGULAR WARNING: To reduce the risk of electric shock, DUCT KNOCKOUT make sure power is switched off at the service SEMI-CIRCULAR (Remove for 3¼” x 10” panel. Lock or tag service panel to prevent power DUCT KNOCKOUT Vertical &...
  • Página 5: Install Hood

    ALLURE™ QS1 SERIES RANGE HOOD Page 5 NON-DUCTED FILTERS INSTALL HOOD If hood is to be installed Non-Ducted: Purchase a set of (2) non-ducted filters from your local distributor or retailer and attach them to the aluminum mesh filters. OPERATION KEYHOLE MOUNTING SCREW Fan: The 3-position rocker switch (on the left) controls the fan. The left position is low speed, center position is off, and right position is Hang hood from (4) Mounting Screws (from parts bag). high speed. An indicator light shows that the fan is on. Slide hood towards wall until mounting screws are engaged Light: The 3-position rocker switch (on the right) controls the lights. in narrow end of (4) Keyholes. Tighten mounting screws The left position is low light intensity, center position is off, and right securely.
  • Página 6: Service Parts

    This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties. To qualify for warranty service, you must (a) notify Broan-NuTone at the address or telephone number below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part.
  • Página 7 “OPERACIÓN” después apague la hornilla. TENGA CUIDADO A FIN DE EVITAR Cómo usar los controles de la campana QUEMADURAS. Si las llamas no se apagan de inmediato, EVACUE Y AVISE A LOS BOMBEROS. “LIMPIEZA” 2. NO LEVANTE NUNCA UNA SARTEN QUE ESTE EN LLAMAS - Usted Mantenga su campana en condiciones óptimas de funcionamiento se podrá quemar. 3. NO UTILICE AGUA, incluyendo toallas de cocina mojadas - puede “PIEZAS DE REPUESTO” resultar una explosión de vapor violenta. Número de las piezas y vista ampliada de los componentes de la 4. Utilice un extinguidor SOLAMENTE si: campana A. Usted sabe que tiene un extinguidor de clas ABC y lo sabe utilizar. B. El incendio es pequeño y contenido dentro del área donde se inició. “GARANTÍA” C. Los bomberos han sido avisados. Garantía limitada de un año y cómo comunicarse con nosotros D. Usted puede combatir el incendio con una salida a su espalda. Registre su producto en línea en: www.broan.com/register * Basado en las recomendaciones para “Seguridad en la Cocina” publi- cadas por la NFPA de los EEUU.
  • Página 8: Preparación Del Lugar Donde Se Va A Instalar La Campana

    CAMPANA EXTRACTORA ALLURE™ QS1 SERIES SERIE QS1 ALLURE™ RANGE HOOD Página 8 Page 8 PREPARACIÓN DEL LUGAR DONDE PREPARACIÓN DEL LUGAR SE VA A INSTALAR LA CAMPANA DONDE SE VA A INSTALAR LA CAMPANA TAPA DE TECHO CONDUCTO DE SISTEMA VERTICAL DE CONDUCTOS 8,3 cm x 25,4 cm O REDONDO DE 17,8 cm REDONDOS DE 17.8 CM (7”)
  • Página 9 CAMPANA EXTRACTORA ALLURE™ QS1 SERIES SERIE QS1 ALLURE™ RANGE HOOD Página 9 Page 9 PREPARACIÓN DE LA CAMPANA PREPARACIÓN DE LA CAMPANA Quite el conector CONDUCTO del regulador de PARA AIRE tiro/conector del Quite el con- interior de la cam- ducto para aire pana. Ponga aparte - fijado con un el conector, con los (1) tornillo. tornillos de montaje y la bolsa de piezas. NOTA: Tenga cuidado de no desconectar CONECTOR DEL REGULADOR...
  • Página 10: Conexión Eléctrica

    CAMPANA EXTRACTORA ALLURE™ QS1 SERIES SERIE QS1 ALLURE™ RANGE HOOD Página 10 Page 10 PREPARACIÓN DE LA CAMPANA CONEXIÓN ELÉCTRICA ADVERTENCIA: Para reducir el riesgo de descar- AGUJERO CIEGO PARA CONDUCTO SEMI- gas eléctricas, asegúrese de apagar el interruptor AGUJERO CIEGO SUPERIOR DEL CIRCULAR CONDUCTO RECTANGULAR de alimentación eléctrica en el panel de servicio. (Quite en el caso de (Quite en el caso de descargas verti- Bloquee o rotule el panel de servicio para evitar...
  • Página 11: Instalación De La Campana

    CAMPANA EXTRACTORA ALLURE™ QS1 SERIES SERIE QS1 ALLURE™ RANGE HOOD Página 11 Page 11 INSTALACIÓN DE LA CAMPANA FILTROS SIN CONDUCTOS NOTA Si la campana se va a instalar en un sistema sin conductos: Compre un juego de (2) filtros para sistemas sin conductos en la tienda distribuidora o minorista de su localidad y sujete a los filtros de malla de alumino. ORIFICIO TIPO BA- CALLAVE OPERACIÓN TORNILLO DE MON- TAJE Cuelgue la campana de los (4) orificios de montaje (que se Ventilador: El interruptor oscilante de 3 posiciones (de la izquierda) encuentran en la bolsa de piezas). Deslice la campana hacia controla el ventilador. La posición hacia la izquierda es la velocidad la pared hasta que los orificios de montaje queden conectados baja, la posición central es apagado y la posición hacia la derecha en el extremo angosto de los (4) orificios tipo bocallave.
  • Página 12: Piezas De Servicio

    COMERCIALIZACION O APTITUD PARA UN PROPOSITO PARTICULAR. 99010309 Juego de filtros para sin conductos, 91.4 cm (2 por bolsa) Durante el período de un año, y a su propio criterio, Broan-NuTone reparará o reemplazará, 99010310 Juego de filtros para sin conductos, 106.7 cm (2 por bolsa) sin costo alguno cualquier producto o pieza que se encuentre defectuosa bajo condiciones normales de servicio y uso.

Tabla de contenido