4.2.1 Cleaning the Condenser Coil
Disconnect machine. Remove front bottom panel and carefully slide out the condensing unit.
The condenser coil requires regular cleaning; recommended every 30-60 days, depending of
the accumulation of dust and grease. If the buildup on the coil consists of only light dust and
debris the condenser coil can be cleaned with a simple brush. Heavier dust build up may
require a vacuum or even compressed air to blow though the condenser coil. If heavy grease is
present there are de-greasing agents available for refrigeration use and specifically for the
condenser coils. The condenser coil may require a spray with the de-greasing agent and then
blown through with compressed air.
Be sure all electrical and mechanical parts are dry before turning on the power.
Never use a high pressure water wash for this cleaning procedure as water can damage the
electrical components located near or at the condenser coil. Do not place filter material in front
of condenser coil. This material blocks air-flow to the coil similar to having a dirty coil!
If you keep the Condenser clean you will minimize your service expense and lower your
electrical costs. Failure to maintain a clean condenser coil can initially cause high temperatures
and excessive run times. Continuous operation with dirty or clogged condenser coils can result
in compressor failures.
To put back the condensing unit in its place, slide in the unit carefully. BE SURE DRAIN PIPE
IS LOCATED OVER THE PAN. Replace front bottom panel
4.2.2 Cleaning the Gasket
Gaskets require regular cleaning to prevent mold and mildew build up and also to keep the
elasticity of the gasket. Gasket cleaning can be done with the use of warm soapy water. Avoid
full strength cleaning products on gaskets as this can cause them to become brittle and prevent
proper seals. Also, never use sharp tools or knives to scrape or clean the gasket which could
possibly tear the gasket and rip the bellows.
Gaskets can easily be replaced and do not require the use of tools or authorized service
persons.
The gaskets can be pulled out of the grove in the door and new gaskets can be "pressed" back
into place.