Descargar Imprimir esta página

AmazonBasics B07XKGM4D4 Manual Del Usuario página 14

Publicidad

Idiomas disponibles

Idiomas disponibles

EN
14
Problem
The product makes
a loud noise during
operation.
Water on floor
Error code
AS
ES
P2
Specifications
B07XHQQ95Y
Rated voltage:
Rated current:
Power input:
Standby power:
Moisture removal:
R.H. range:
Rated IEF:
Water tank capacity:
Refrigerant:
Fan IP rating:
Power cord and plug:
Air flow:
Sound emission:
Cause / Solution
The air filter is clogged.
The product is tilted instead of staying upright
as it should be.
The floor surface is not leveled.
The drain hose connection may be loose.
The drain hose outlet (P) might be opened.
Cause / Solution
Humidity sensor error.
Bring the product to a repair service.
Temperature sensor error.
Bring the product to a repair service.
Water container is full.
Empty the bucket.
Water container is not placed properly.
Rearrange the water container until it fits
properly in the housing.
115 V~, 60 Hz, single phase
max. 7.8 A
max. 810 W
1 W
50 pints/day (23.66 L/day)
35 – 85 % R.H.
0.48 gal/kWh (1.8 L/kWh)
1.59 gal (6 L)
R410A, 7.4 oz (210 g)
IP04
3- wire; grounded
11301/13066 cft/h (320/370 m
≤54 dB(A)
/h)
3

Publicidad

loading

Este manual también es adecuado para:

B07xhqq95yB07xkglmr8