E N G L I S H
3. Water is sucked back during
steaming, even after having
restored the correct level (as
per Pos. 2).
4. No water in the boiler with
consequent heating elements
burning due to the failure of
the electronic level control
group.
5. No water in the boiler due to a
failure of the water feeding
group (electric valve, tubes
and connections).
6. The pump does not work.
C H A P T E R 4
3. Causes:
a) The electric feeding valve is
out of order or dirty, and
prevents the pin from closing
tight, water leaks in.
b) Water is not drained every day
from the boiler, and foam
develops.
c) The boiler level gauge has
lime scales (mostly on its end):
the machine does not operate
correctly and water is fed in
continuously.
d) Interruption on wires and on
connection contacts of the
level gauge on the electric
panel.
e) Electronic group failure.
4. If the correct water level into the
boiler is not restored in 20
seconds the electronic group
and
the
level
automatically
switch
heating
elements,
burning
them.
failure of the level gauge or of
the
electronic
group
prevent this automatism and
would
burn
the
elements.
5. Causes:
a) No water from the feeding
system.
b) The water filter assembled on
the
electric
feed
clogged.
c) Electric feed valve failure.
d) Lime scales clog tubes and
connections.
6. Causes:
a) The pump rotor is blocked
scales.
Page 4-7
3. Solutions:
a) Replace the water feeding
valve.
b) Remember to drain the boiler
every evening so as keep it
free from foam and scales.
c) Disassemble the level gauge
and carefully remove lime
scales from the gauge body
by means of emery cloth.
Make
pin/electrode does not rotate
inside the gauge holder, if
necessary screw the upper
nut tight.
d) Restore continuity on wires
and
between level gauge and
electric panel.
e) Replace
station inside the electric
panel.
4. Replace the level gauge or the
electronic
Performs
gauge
procedure as per POS. 3C.
off
the
avoiding
Obviously
a
would
heating
5. Solutions:
a) Make sure that water is fed
into the machine by removing
the rubber pipe mounted on
the feeding pipe holder.
b) Clean
valve
is
disassembling
feed pipe holder.
c) Check if the coil of the feed
valve is burned, if so replace
it.
d) Free and clean tubes and
connections
scales.
6. Solutions:
by
a) Try to operate the pump rotor
by rotating the motor shaft by
means of a screw driver
applied into the slit on the
pump motor side. If this fails,
the pump cover must be
disassembled, the brass fan
must be cleaned and
correct rotation checked.
E N G L I S H
sure
that
the
connection
contacts
the
electronic
group
or
both.
the
checking
the
filter
net
by
the
rubber
from
lime
the