Step 5. Electrical connections
WARNING
• Disconnect all electrical power of the main circuit breaker or fuse box before
installing.
• BEFORE OPERATING OR TESTING, follow the grounding requirements on pages 14
in this manual. Improper connection of the grounding plug can result in a rick of
electric shock.
• All gas cooktops come with a power cord. The power cord is connected to the
bottom of the cooktop. Please review "Electrical requirements" on pages 13.
• The electrical system, including the power cord, is preinstalled and prewired at
the factory. Altering any part of this system may result in a short or overload.
1. Plug in the power cord. Make sure the outlet meets local or national electrical
codes as referenced on pages 13.
2. Check the gas supply line to make sure it did not get damaged and it stayed
connected during positioning.
Install_NA30R5310FG_AA_DG68-01133A-00_EN.indd 17
Step 6. Assemble the cooktop burners
CAUTION
• Do not operate the cooktop burners without all burner parts in place.
• Be careful not to push in any cooktop controls while removing the cooktop
burner. A slight electrical shock might result which could cause you to knock
over hot cookware.
• Do not remove the top or touch the electrode of any burner while another
burner is turned on. Electrical shock might result.
1. Position cooktop burner heads on top of
2. Place the matching size caps on top of
30" - NA30*5310F*
36" - NA36*5310F*
the cooktop burner manifolds as shown
on the left. The electrodes will fit into
the slot in the bottom of the heads. Make
sure the cooktop burner heads are flat
and parallel with the cooktop.
each cooktop burner head.
English 17
2019-04-12
12:13:36