Descargar Imprimir esta página

Ingersoll Rand SCHLAGE BE469NX Guia Del Usuario página 15

Publicidad

Idiomas disponibles

Idiomas disponibles

PRoBlem
After entering a User
Code to unlock the
lock, the yellow dot is
flashing and there is a
delay before unlock.
Inside Schlage Button is
flashing but no alarm is
sounding.
3 Red
when Outside
Schlage Button is
pressed.
Pressing Outside
Schlage button when
deadbolt is unlocked
does not cause
deadbolt to relock.
Deadbolt will not
extend or retract as
expected.
Deadbolt requires two
attempts to lock or
unlock.
Alarm will not sound.
Alarm sounds too
frequently/ false alarm,
or not frequently
enough.
The tamper alert is not
sounding.
The bolt was operating
smoothly, but now is
not.
soUNDs
lIGHTs
Several
Outside
beeps
yellow dot
flashing
Inside
Schlage
Button
flashes
every 5
seconds
3 Red
1 long
1 Red
beep
Green
Alarm
solUTIoN
Battery is low and should be replaced. See
Replacing the Batteries on page 4.
Battery is critical and must be replaced.
See Replacing the Batteries on page
4.
The Lock & Leave feature is not enabled.
See enable/Disable lock & leave on
page 7.
If you do not want to enable Lock &
Leave, then enter a valid User Code to
lock the door.
Adjust bolt/frame alignment. Browse to
answers.schlage.com for help.
Deadbolt/frame alignment is marginal.
Adjust door/frame for best operation.
Browse to answers.schlage.com for help.
Turn on Alarm.
Sensitivity level is too high (at 1 or 2)
or too low (at 4 or 5) and should be
adjusted. See adjusting the sensitivity
level on page 9.
There is a 60-second delay before device
alarms to allow you to exit and lock the
door. See alarm setting Descriptions
on page 8.
The bolt has become soiled. Clean with
mild detergent and warm water.
The strike has become worn. Flip
the strike over for continued smooth
operation.
15

Publicidad

loading

Este manual también es adecuado para:

Schlage be469