EU - Declaration of Conformity
Technical data
Gas flo rate
Cooling
Highest temperature of
cooling medium*
Minimum quantity of
cooling flow
Lowest pressure of entry
Highest pressure of entry
Required cooling unit
capacity (min.)
Abb. 1:
Technical data
*)
only in combination with recommended Lorch water cooling equipment
11
EU - Declaration of Conformity
We herewith declare that this product
was manufactured in conformance with
the following norms: EN 60974-1:2012,
EN 60 974-7:2013, in conformance with
the guidelines 2014/35/EU, 2014/30/EU,
2011/65/EU.
2015
Wolfgang Grüb
Director
Lorch Schweißtechnik GmbH
12.15
a-LTG/i-LTG
900
1700
l/
5 - 12 7 - 15 7 - 18 7 - 18 7 - 20 7 - 20 7 - 20 8 - 22 8 - 22
min
Gas
Gas
°C
l/
min
bar
bar
W
2600
2800
1800 1800sc 2000
Gas
Gas Water Water Water Water Water
60
1,0
2,5
5,0
530*
a-LTW/i-LTW
3000
60
60
60
1,0
1,0
1,0
2,5
2,5
2,5
5,0
5,0
5,0
530*
530*
530*
4500
60
1,0
2,5
5,0
530*
- 29 -