2. Reference value of each parameter
1
Model
2
GasType
3
Gas Pressure
4
FA
F9
Fn
5
PH
FH
6
PL
FL
7
dH
8
Fd
3. Test preparation
Steps:
1. Demount the screws on the top of gas distributor and gas inlet, and connect to silicone tube
2. Demount the wire from the bottom shell, find the mounting hole and pass the silicone tube
through the mounting hole.
3. Use some soft filler to block the mounting hole and cover the machine with the shell.
4. Mount micro-manometer to test the gas pressure.
ARGON11BUT
G20
2000Pa
00
Choose C or B type exhaust pipe
00 corresponds to 1m short smoke pipe
01 corresponds to 4m long smoke pipe
C32 only for 1m
1250Pa
60
220Pa
32
460Pa
25
Choose C or B type exhaust pipe
00 corresponds to 1m short smoke pipe
01 corresponds to 4m long smoke pipe
To test secondary gas
To test primary gas
25
ARGON11GN
G30
2900Pa
01
C32 only for 1m
1880Pa
56
270Pa
30
460Pa
25