4. Enter into forced mode and set the PH parameters for the secondary gas pressure
PH parameter adjustment: make sure the shell and exhaust pipe is in its place. Enter into
forced mode, please refer to steps 1, 2 and 3. If there is EA fault alarm, cut off the power and
wait for 1min and then repeat the aforesaid operations again.
When in PH parameter mode, run the machine and begin to adjust the secondary gas
pressure, in this time, the supply gas pressure should be adjusted to 2900Pa (G30) or 2000Pa
(G20). Tap the on/off icon, when it displays digits, tap up icon to increase the value or tap
down icon to decrease the value and tap on/off iron and it displays PH.
The steps for entering forced mode is as follows:
1.Water in
3.1. Power on
3.3. Long-tap the down icon until
it displays PP and enter to forced
mode
2. Power off
3.2 Quickly long-tap the down
icon when you hear "di".
4. Tap on/off icon to enter to FA
Tap the on/off icon, when it
displays digits. Select the
corresponding gas source code.
26
V.3