When the alignment LED [D] flashes red and green alternately an
alignment problem occurs. Open the cover and slowly adjust the
horizontal and/or vertical angle [F] of the lens [C].
•
In case somebody opens the cover, the tamper switch [E] is released
and the tamper contact is closed:
[6] – [7]: closed contact
8.
Maintenance
•
Make sure the cover [H] and reflector are clean at all times. Remove
dirt with a soft lightly moist lint‐free cloth.
9.
Technical Specification
cover
housing
IP-rating
input voltage
transmitter
range
beam spreading angle
contact capacity
response time
delay time of relay
operating temperature
storage temperature
dimensions
weight
Use this device with original accessories only. Velleman nv cannot be
held responsible in the event of damage or injury resulted from
(incorrect) use of this device. For more info concerning this product,
please visit our website www.velleman.eu. The information in this
manual is subject to change without prior notice.
© COPYRIGHT NOTICE
The copyright to this manual is owned by Velleman nv. All worldwide rights reserved.
This manual is copyrighted. No part of this manual may be copied, reproduced,
translated or reduced to any electronic medium or otherwise without the prior
written consent of the copyright holder.
06.12.2010
PMMA (Polymethyl methacrylate)
ABS (Acrylonitrile butadiene styrene )
66
12 - 250V AC or DC
infrared LED, wavelength 750nm
up to 10m
1.5°
0.5A / 120VAC (1A / 30VDC)
10ms
100ms
-25~+60°C
-35~+80°C
transmitter
122 (H) x 60 (W) x 62 (T)
reflector
Ø80 x 7mm
±200g
PEM10D2
7
Rev. 01
©Velleman nv