OPERATION
EN
STORING MACHINE
1. Remove brush/pad driver from machine and neatly
coil cord around cord hook and handle.
2. Store machine in a dry area in the upright position.
WARNING: Electrical Shock Hazard.
Do Not Use Outdoors. Do Not Expose to Rain.
Store Indoors.
TROUBLE SHOOTING
PROBLEM
Machine does not
operate.
Machine operates
with a wobble or jerky
motion.
Machine circuit
breaker trips
continuously.
8
CAUSE
Faulty power cord.
Tripped circuit breaker.
Tripped building circuit breaker.
Faulty machine wiring.
Faulty On/Off handle switch.
Faulty motor.
Capacitor burned out (Single speed models). Contact Service Center.
Rectifier burned out (Dual speed models).
Soiled Pad.
Improper pad/brush for application.
Pad driver/brush not installed correctly.
Pad/brush unevenly worn.
Pad not properly centered on pad driver.
Heavily soiled pad/brush.
Improper pad/brush for application.
Defective circuit breaker.
Worn carbon brushes in motor.
FM- -17- -SS / FM- -20- -SS / FM- -20- -DS / FM- -43- -SS / FM- -51- -SS / FM- -51- -DS (04- -10)
RECOMMENDED STOCK ITEMS
Refer to the Parts List manual for recommended stock
items. Stock Items are clearly identified with a bullet
preceding the parts description. See example below:
SOLUTION
Contact Service Center.
Reset circuit breaker on machine.
Reset circuit breaker in building.
Contact Service Center.
Contact Service Center.
Contact Service Center.
Contact Service Center.
Replace Pad.
Change to proper pad/brush.
Remove and reinstall pad driver/brush.
Replace pad/brush.
Remove and reinstall pad.
Clean or replace pad/brush.
Change to proper pad/brush.
Contact Service Center.
Contact Service Center.