Descargar Imprimir esta página

Senco PC1010 Instrucciones De Operación página 10

Compresor de aire eléctrico
Ocultar thumbs Ver también para PC1010:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 145
INITIAL SET-UP:
1.
Read safety warnings before setting-up air compressor.
LOCATION:
In order to avoid damaging the air compressor, do not incline the air compressor
transversely or longitudinally more than 10°.
1. Place air compressor at least 30cm away from obstacles that may prevent proper ventilation.
Do not place air compressor in an area:
-where there is evidence of oil or gas leaks.
-where flammable gas vapors or materials may be present.
WARNING
Serious injury or death may occur if electrical sparks from motor and pressure switch
come in contact with flammable vapors, combustible dust, gases or other
combustible materials. When using the air compressor for spray painting, place the
air compressor as far away I from the work area as possible, using extra air hoses instead of
extension cords.
-where air temperatures fall below 0°C or exceed 40°C .
-where extremely dirty air or water could be drawn into the air compressor.
ELECTRICAL:
DANGER
Improper connection of the equipment-grounding conductor can result in a risk
of shock or electrocution. Check with a qualified electrician or service personnel
if you are in doubt as to whether the outlet is properly grounded. Do not use any type of
adapter with this product. If repair or replacement of the cord or plug is necessary, do not
connect the grounding wire to either flat blade terminal. The wire with insulation having
an outer surface that is green with or without yellow stripes is the grounding wire.
WARNING
This product must be grounded. If there should be a malfunction or breakdown,
grounding provides a path of least resistance for electric current to reduce the
risk of electric shock. This product is equipped with a cord having an equipment-
grounding conductor and a grounding type plug. The plug must be plugged into an
appropriate outlet that is properly installed and grounded in accordance with all local
codes and ordinances.
1. SENCO® DOES NOT RECOMMEND THE USE OF EXTENSION CORDS as this can create power loss and
overheating of the motor. Use of an additional air hose is recommended rather than an extension cord. If use of an
extension cord is unavoidable, it should be plugged into a GFCI found in circuit boxes or protected receptacles.
When using an extension cord, observe the following:
Use only 3-blade extension cords that have 3-blade grounding-type plugs and 3-slot cord connectors that will
accept the plug from the product. Use only extension cords having an electrical rating not less than the rating of
the product. Do not use damaged extension cords. Examine extension cord before using and replace if damaged.
Do not abuse extension cord and do not yank on any cord to disconnect. Keep cord away from heat and sharp
edges. Always shut off the air compressor switch before removing the plug from the receptacle.
PREPARATION
CAUTION
Cable Length
Up to 8 meters
Up to 30 meters
Up to 50 meters
Up to 75 meters
Wire Gauge
12
AWG
10
AWG
8
AWG
6
AWG
10

Publicidad

loading