In user mode and shutdown state, press "△" and "▽"
simultaneously for 5 seconds to enter the menu page. Press "△"
and "▽" to switch the menu. The sequence is shown below:
P00->P01->P02->P03->P04->P05
In the menu mode: Press the "1" key to enter the setting page.
Press the short "△" and "▽" keys to modify the parameters under
the corresponding menu.
In the Settings page, the parameters will flash. Press 1 to confirm
the Settings and return to the menu page.
Automatically exit the menu mode without operation timeout of 5
seconds, and set and save the parameters to confirm the
modification.
7. Energy-saving mode:
If there is no operation on the key within 30 seconds, the
energy-saving mode is entered. At this time, the display of the
controller is closed and the controller enters low power consumption.
Press any key to exit the energy-saving mode. In energy-saving
mode, the key command does not take effect.
8. Overheat protection
In order to better protect the motor, if the system runs 5 meters in 18
minutes, it will enter the overheat protection mode. The overheat
protection needs to be detected in the shutdown state, and the
display screen shows HOT. At this time, other functions of the
manual controller are closed and the key cannot be used.
After 18 minutes, the controller will automatically exit the overheat
protection mode, or exit the overheat protection mode after power
failure and restart.
9. Child Lock
Press "▽", "△" and "1" key for 5 seconds. If "LOC" is displayed on
the controller, the system is locked and cannot rise or descend; In
the locked state, press "▽", "△" and "1" key for 5 seconds. When
the display of the controller changes from "LOC" to a normal digit
display, the system is unlocked.
14
Fault code table
When there is a fault, it beeps twice to remind the user that the
machine is in a fault state and cannot be used. After the fault is
completely cleared, it beeps twice to remind the user that it can be
used normally.
Fault code
Reason
E01▽
Motor 1 is disconnected
E02▽
Motor 2 is disconnected
E03▽
Motor 1 overcurrent
E04▽
Motor 2 overcurrent
E05▽
The hall line of motor 1
is not inserted
The hall line of motor 2
E06▽
is not inserted
E07▽
EEProm
E08▽
Resistance
Solution
After detecting that there is no
problem with the line, long press the
down key for 5S to reset or restart
after power failure.
After detecting that there is no
problem with the line, long press the
down key for 5S to reset or restart
after power failure.
After detecting that there is no
problem with the line, long press the
down key for 5S to reset or restart
after power failure.
After detecting that there is no
problem with the line, long press the
down key for 5S to reset or restart
after power failure.
After detecting that there is no
problem with the line, plug in the Hall
interface
After detecting that there is no
problem with the line, plug in the Hall
interface
In case of abnormal resistance, check
whether there are obstacles. If the
sensitivity is not suitable, please refer
to the menu to adjust the sensitivity.
15