Technical Data
Service connection ............................................................................................................................................... 230 V~50 Hz
Motor output S3/ 60% ...................................................................................................................................................1,8 kW
Number o cylinders ...................................................................................................................................................................1
Suction capacity .......................................................................................................................................................... 260 l/min
Free air delivery............................................................................................................................................................ 175 l/min
Max. working pressure .....................................................................................................................................................10 bar
tank capacity ............................................................................................................................................................................ 50 l
Weight ..................................................................................................................................................................................... 31 kg
Degree o protection.......................................................................................................................................................................IP 20
Protection class ........................................................................................................................................................................................1
Sound power level L
*Measured according to 2006/42/EC
service manual. Act responsibly toward third parties.
In case o any doubts about connection and
operation reer please to our customer center
Preserve all the documentation so that anyone who
uses the compressor can consult this beorehand.
Specied Conditions Of Use
The compressor can only be used or the produc-
tion o compressed air to be used at home and by
handymen. – Respecting technical data and saety
precautions.
The compressed air produced by the
compressor cannot not be used or pharmaceuti-
cal, ood or medical purposes or to ll the air
bottles o scuba divers.
The compressor must be used in a suitable
environment (well ventilated with an ambient
temperature o between +5°C and +40°C) and
never in places with dust, acids, vapors, explosive
or ammable gases.
Do not use this product in any other way as stated
or normal use. Not observing general regulations
in orce and instructions rom this manual does not
make the manuacturer liable or damages.
* .......................................................................................................................................................... 97 dB(A)
WA
Read and understand the
operating instructions beore
using the appliance. Abide by all
the saety measures stated in the
Safety instructions
WARNING! Electric shock! There is a risk of
an injury caused by electric shock!
Operation is only allowed with a safety
switch against stray current (RCD max. stray
current of 30mA).
Check the voltage. Technical data given on the type
label must correspond with electric network voltage.
Insert the plug o the electrical cable in a socket o
suitable shape, voltage and requency complying
with current regulations.
Use extension cables with a maximum length o 5
meters and with a cable cross-section o not less than
1.5 mm2. Use o extension cables o dierent length
and cross-section and also o adapters and multiple
sockets should be avoided.
Check the cable and/or socket or damages beore
the appliance putting into operation.
To avoid danger, a damaged mains supply pipe must
be replaced by the manuacturer. Do not under any
circumstances attempt any repair yoursel.
Never let the compressor come into contact with
water or other liquids and never direct the jet o
liquids sprayed by tools connected to the compressor
towards the compressor: as the appliance is live, this
could cause electrocution or short-circuits.
Never use the appliance with bare eet or wet hands
or eet.
Never yank the power cable to disconnect the plug
rom the power outlet or to move the compressor.
Warning: the compressor may restart when power is
restored ollowing a blackout.