Installing Support Brackets and Center Plate
NOTE: Use center plate (D) when mounting pattern for wall plate of mount is narrower than opening
3-1
between interface plates (A).
Attach support brackets (C) to rear of wall plate (B) using 1/4-20 x 1" round phillips head screw (G),
1/4" flat washer (J) and 1/4-20 flanged serrated locknut (H) for each support bracket as shown below.
NOTE: Be sure flange of support bracket faces inside of interface plate and wall plate. NOTE: Do not
fully tighten fasteners.
Skip to step 3-3 if not installing center plate.
Swing adapter brackets (C) away from front of
3-2
mount. Slide center plate (D) behind interface
plate (A) and center between the two interface
plates. Align top and bottom holes of interface
plate with slots of center plate. Hand thread
1/4-20 x 1" round phillips head screw (G) and
1/4" flat washer (J) through top hole only.
G
J
Visit the Peerless Web Site at www.peerlessmounts.com
A
D
B
A
Swing adapter brackets (C) towards front of
3-3
mount. Guide top adapter bracket through top
screw and fasten using 1/4-20 flanged serrated
locknut (H). Align hole of bottom adapter bracket
with bottom hole and fasten using 1/4-20 x 1"
round phillips head screw (G), 1/4" flat washer (J)
and 1/4-20 flanged serrated locknut (H).
H
9 of 30
For customer care call 1-800-865-2112 or 708-865-8870.
G
J
H
C
H
J
G
J
G
ISSUED: 07-22-08 SHEET #: 120-9054-1