Descargar Imprimir esta página

Aube Technologies TH115 120S Guía Para El Usuario página 10

Publicidad

Idiomas disponibles

Idiomas disponibles

Owner's Guide
Connecting the floor sensor / remote control
Insert the floor sensor cable through one of the two
openings on the wallplate and connect the sensor
wires to terminals 3 and 4 (no polarity).
The sensor wires must not come in contact with the
electrical wires and must be routed outside the
electrical box and follow the wall down to the floor.
Position the sensor cable such that it does not come in
contact with the floor heating wires. The sensor must
be centered between two floor heating wires for best
temperature control.
Do NOT staple the sensor head (the plastic end) to the
floor. Doing so might damage the sensor. Any damage
might not be noticeable during testing but can become
apparent several days later.
If you wish to connect a remote control device (see
page 17), insert the wires (use 18- to 22-gauge
flexible wires) through one of the two openings on the
wallplate and connect them to terminals 1 and 2 (no
polarity).
8
Remote
control
Floor
device
temperature
sensor

Publicidad

loading