Technical Specifications
Model
120S
240S
240D
Display
range: 0°C to 70.0°C (32°F to 158°F)
Ambient setpoint range (A/AF
Floor setpoint range (F
mode): 5.0°C to 40.0°C (40°F - 104°F)
Floor limit range (AF
mode): 5.0°C to 40.0°C (40°F - 104°F)
Resolution: 0.5°C (1°F)
Heating cycle
length: 15 minutes
Data
protection: In the event of a power failure, most settings are saved. However the time and Daylight Saving Time must
be set if the power failure lasts more than 6 hours. The thermostat will return to the mode that was active prior to the power
failure.
Supply
Maximum current
120 VAC, 50/60Hz
240 VAC, 50/60Hz
208 VAC, 50/60Hz
240 VAC, 50/60Hz
208 VAC, 50/60Hz
modes): 5.0°C to 30.0°C (40°F - 86°F)
TH115 (120S/240S/240D models)
Maximum wattage
16.7 A
2000 W
4000 W
16.7 A
3470 W
3600 W
15 A
3120 W
19
Wiring
4 wires / single pole
4 wires / single pole
4 wires / double pole