Descargar Imprimir esta página

AEG SBE 570 R Manual Original página 9

Ocultar thumbs Ver también para SBE 570 R:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 13
TECHNICAL DATA
Percussion Drill/Screwdriver
Rated input ..............................................................................
Output ......................................................................................
No-load speed .........................................................................
Speed under load max. ...........................................................
Rate of percussion under load max .........................................
Static jamming moment*, 1st gear...........................................
Drilling capacity in concrete .....................................................
Drilling capacity in brick and tile ..............................................
Drilling capacity in steel ...........................................................
Drilling capacity in wood ..........................................................
Drill opening range ..................................................................
Drive shank..............................................................................
Chuck neck diameter ...............................................................
Weight according EPTA-Procedure 01/2003 ...........................
* Measured according to AEG norm N 877318
Noise information
Measured values determined according to EN 60 745.
Typically, the A-weighted noise levels of the tool are:
Sound pressure level (K = 3 dB(A)) .......................................
Sound power level (K = 3 dB(A)) ............................................
Wear ear protectors!
Vibration information
Total vibration values (vector sum in the three axes)
determined according to EN 60745.
Vibration emission value a
:
h
Percussion drilling into concrete ..............................................
Uncertainty K ...........................................................................
Drilling into metal .....................................................................
Uncertainty K ...........................................................................
WARNING
The vibration emission level given in this information sheet has been measured in accordance with a standardised test given
in EN 60745 and may be used to compare one tool with another. It may be used for a preliminary assessment of exposure.
The declared vibration emission level represents the main applications of the tool. However if the tool is used for different
applications, with different accessories or poorly maintained, the vibration emission may differ. This may significantly increase
the exposure level over the total working period.
An estimation of the level of exposure to vibration should also take into account the times when the tool is switched off or
when it is running but not actually doing the job. This may significantly reduce the exposure level over the total working period.
Identify additional safety measures to protect the operator from the effects of vibration such as: maintain the tool and the
accessories, keep the hands warm, organisation of work patterns.
WARNING! Read all safety warnings and all
instructions, including those given in the accompanying
brochure. Failure to follow the warnings and instructions
may result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future reference.
SAFETY INSTRUCTIONS
Wear ear protectors when impact drilling. Exposure to
noise can cause hearing loss.
Use auxiliary handles supplied with the tool. Loss of
control can cause personal injury.Appliances used at many
different locations including open air must be connected via
a current surge preventing switch.
Hold power tool by insulated gripping surfaces, when
performing an operation where the cutting accessory
may contact hidden wiring or its own cord. Contact with
a „live" wire will also make exposed metal parts of the power
tool „live" and shock the operator.
Appliances used at many different locations including open
air should be connected via a residual current device of
30 mA or less.
Always wear goggles when using the machine. It is
recommended to wear gloves, sturdy non slipping shoes
and apron.
16
ENGLISH
SBE 500 R
SBE 570 R
.........500 W ..............570 W
.........250 W ..............285 W
....0-2650 min
.... 0-2700 min
-1
-1
.......1800 min
........1600 min
-1
-1
.....27000 min
......24000 min
-1
-1
...........21 Nm ..............23 Nm
...........13 mm..............15 mm
...........15 mm..............18 mm
...........10 mm..............13 mm
...........20 mm..............30 mm
.....1,5-10 mm....... 1,5-13 mm
...1/2"x20 ............1/2"x20
...........43 mm..............43 mm
..........1,6 kg ...............1,7 kg
...........95 dB (A) .........95 dB (A)
.........106 dB (A) .......106 dB (A)
...........26 m/s
.............30 m/s
2
2
..........5,6 m/s
............2,5 m/s
2
2
.............6 m/s
...............6 m/s
2
2
.............2 m/s
............1,5 m/s
2
2
Sawdust and splinters must not be removed while the
machine is running.
Always disconnect the plug from the socket before carrying
out any work on the machine.
Only plug-in when machine is switched off.
Keep mains lead clear from working range of the machine.
Always lead the cable away behind you.
When working with large drill diameters, the auxiliary handle
must be fastened in a right angle with the main handle (see
illustrations, section Twisting the handle).
When working in walls ceiling, or floor, take care to avoid
electric cables and gas or waterpipes.
SPECIFIED CONDITIONS OF USE
The percussion drill/screwdriver can be universally used for
drilling, percussion drilling, screwdriving and cutting screw
threads.
Do not use this product in any other way as stated for
normal use.
MAINS CONNECTION
Connect only to single-phase a.c. current and only to the
system voltage indicated on the rating plate. It is also
possible to connect to sockets without an earthing contact
as the design conforms to safety class II.
EC-DECLARATION OF CONFORMITY
We declare under our sole responsibility that this product is
in conformity with the following standards or standardized
documents.
EN 60745-1:2009 + A11:2010
EN 60745-2-1:2010
EN 55014-1:2006 + A1:2009 + A2:2011
EN 55014-2:1997 + A1:2001 + A2:2008
EN 61000-3-2:2006 + A1:2009 + A2:2009
EN 61000-3-3:2008
in accordance with the regulations
2011/65/EU (RoHs)
2006/42/EC
2004/108/EC
Winnenden, 2012-09-12
Rainer Kumpf
Director Product Development
Authorized to compile the technical file
MAINTENANCE
The ventilation slots of the machine must be kept clear at all
times.
If the machine is mainly used for percussion drilling,
regularly remove collected dust from the chuck. To remove
the dust hold the machine with the chuck facing down
vertically, and completely open and close the chuck. The
collected dust will fall from the chuck. It is recommended to
regularly use cleaner for the clamping jaws and the
clamping jaw borings.
Use only AEG accessories and AEG spare parts. Should
components need to be replaced which have not been
described, please contact one of our AEG service agents
(see our list of guarantee/service addresses).
If needed, an exploded view of the tool can be ordered.
Please state the ten-digit No. as well as the machine type
printed on the label and order the drawing at your local
service agents or directly at: AEG Electric Tools GmbH,
Max-Eyth-Straße 10, D-71364 Winnenden, Germany.
SYMBOLS
Please read the instructions carefully before
starting the machine.
Always disconnect the plug from the socket
before carrying out any work on the machine.
Accessory - Not included in standard
equipment, available as an accessory.
Do not dispose of electric tools together with
household waste material! In observance of
European Directive 2002/96/EC on waste
electrical and electronic equipment and its
implementation in accordance with national
law, electric tools that have reached the end
of their life must be collected separately and
returned to an environmentally compatible
recycling facility.
Class II construction, tool in which protection
against electric shock does not rely on basic
insulation only, but in which additional safety
precautions, such as double insulation or
reinforced insulation, are provided.
ENGLISH
17

Publicidad

loading

Este manual también es adecuado para:

Sbe 500 r