Machine Use - LAVOR Pro GV8,6 Manual De Instrucciones

Generador de vapor
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Filling the tanks with water and detergent
Fill the tanks with water and detergent in the following way:
- Stop the machine by turning the main switch to OFF
- Open the upper movable protection to reach the tanks
- Fill the tanks
- Close the upper movable protection.
WARNINGS
- Never use distilled water! The machine may not run
correctly.
Boiler steam blow-off
Follow the instructions below:
- A few minutes before the end of the work shift, turn off the boiler by pressing the BOILER
START luminous green push-button. Keep on using the steam gun until the pressure gauge
indicates a value of 0-1 BAR;
- Carefully open the boiler drain cock, situated on the machine right side and drain all the
water from the boiler into a suitable container;
- Once the water has been drained up completely, close the cock;
Drain
cock
Description of the start sequence
After carrying out all the connections and the preventive inspections described in the previous chapters, start the machine according to
the following instructions:
1)
Before starting the generator, fill the tanks up to the level with water and detergent.
2)
Turn the main switch situated on the control panel to ON.
3)
Press the BOILER START green luminous push-button on the control panel board.
4)
Press the GUN START orange luminous push-button on the control panel board.
5)
If the water level in the boiler is already correct, the thermoregulator will indicate the temperature value previously set by the
operator after approx. 7-10 minutes. At this point, the steam gun can be used.
6)
If there is no water in the boiler, the TANK WATER LEVEL red pilot light will turn on. It will turn off when the water reaches the
level in the boiler; at this point, the boiler will start producing steam. Once the desired pressure value has been reached, it will
be possible to use the steam gun.
7)
If the WATER LEVEL IN THE TANK red pilot-light flashes and an acoustic alarm is heard, it means that there is no water in the
tank. Fill the tank (see "Filling the tanks with water and detergent").
If this trouble occurs during the normal use of the generator, after filling the tank with water, it will be necessary to first turn the
boiler off and then on by means of the BOILER START green luminous push-button.
Detergent