Introduction
The LA GARD 700 Series Reset Box is compatible with LA GARD Series Models 701-705 as well as 700 BASIC.
The Reset Box is not compatible with Legacy LA GARD products that do not have a BAT Port (LA GARD BASIC,
LA GARD Combogard Pro, LA GARD Auditgard).
Connect the Reset Box
Once the Reset Box is connected to a safe lock, deleted users cannot be recovered. All settings will be
restored to the default values. While the Reset Box is connected to the lock, ALL communication from
the Keypad is rejected. Access to the secured area MUST be maintained (keep the access door open)
until the Reset Box is disconnected from the lock. If the access door is closed, the lock will have to be
drilled to re-open.
Model
Reset Lock 700 Series Models 731-734
Reset
All Users except for Master will be deleted
Details
Master User Combination will be reset to
default value 12345678
All Settings will be restored to default
values
Reset Steps
1.
Disconnect the safe lock from all power
sources. The safe lock should also be
disconnected from any Keypad or
Multiplexer prior to connecting the Reset
Box.
2. Insert batteries into the Reset Box.
3. Connect the Reset Box to the Safe Lock
BAT port.
4. The LED will illuminate and then stop
when the reset is complete. DO NOT
unplug the box before the reset is
complete.
5. Disconnect the Reset Box from the Safe
Lock.
6. Once successfully reset, the Master User
Combination will be reset to 12345678.
7. Reconnect the Safe Lock to the system.
Note: If the Reset Box LED does not turn on,
disconnect the Reset Box, and repeat steps 1
and 2.
Reset 700 Series Models 7B1-7B3
1.
2. Press and hold the 0 key for 10 seconds to
3. Connect the Reset Box to the Safe Lock
4. The Reset Box LED will illuminate for
5. Disconnect the Reset Box from the Safe
6. Once successfully reset, the Manager
7. Reconnect power to the lock. Test by
Note: If the Reset Box LED does not turn on,
disconnect the Reset Box, and repeat steps 1
and 2.
dormakaba USA Inc. | Reset Box User Guide 7039.0521 Rev C 07/22
Super Master Reset Code will return to
default 55555555
Manager Combination will return to
default 123456
User will be deleted
Remove batteries or disconnect the lock
from any power source.
discharge any residual energy.
BAT port.
approximately 3 seconds, then stop when
the reset is complete.
Lock.
Combination will be reset to the default
123456 and the Super Master Reset Code
will return to default 55555555.
opening the lock with the default
Manager Combination of 123456.

Publicidad