Operation and Maintenance Documentation of air curtains GUARD PRO v202301
Installation of connector inside the curtain
Installation of connector at the back of the curtains
Horizontal assembly
To mount the curtain horizontally in a proper
way, keep the distance of min 300mm from the
rear side of the device.
To mount the GUARDPRO curtain to the ceiling,
use the GUARDPRO multi-purpose connector.
Mounting pins of diameter 11 may be attached
to the connector (not included in the delivery).
Vertical assembly
To mount the curtain vertically make sure the air
outlet of the curtain is as close as possible to the
doorway and air gap is at the height of the upper
edge of the entry. Please, make sure to keep the
distance of about 300 mm between the outlet
casing and the wall.
To mount two GUARD PRO curtains one above
the other, it is necessary to use the GUARDPRO
multi-purpose connector to install the curtain to
the wall.
To mount GUARD PRO curtain to the floor, use
vertical holder/support, which is used to attach
the curtain to the EURO pallet (for the period of
transport). The support is included in the
delivery. The curtain must be attached to the
floor from each side and its rear side as shown in
Figure.