Brew Monk 057.700.30 Instrucciones De Uso página 28

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 62
EN - Instruction Manual Brew Monk
• The blue valve, on the circulation pipe, in horizontal position closes the ball valve. The blue
valve, on the circulation pipe, in vertical position opens the ball valve.
• Switch off the pump when you close the blue valve for longer than 5 seconds.
• Always close the blue valve and switch off the pump before removing the curved pipe (11).
• Do not run the pump during wort boiling.
• It is not recommended to use the pump for pumping the wort after cooling, as there is no
filter on the pump inlet. This can cause brew debris to enter the pump, potentially blocking
and damaging the system.
2.2 Bazooka Filter Assembly
Attach the bazooka filter (12) on the male thread inside the Brew Monk using the clip bind and
tighten by using a screw driver (see pictures below).
2.3 Overflow Pipe Assembly
2.3.1 Malt Pipe Assembly Outside the Brew Monk
Step 1
28
B
F
G
C
D
E
A
H
I
1 x top malt screen (1 centre
A
hole + 2 small holes)
1 x bottom malt screen
B
(1 centre hole)
2 x handle
C
1 x short pipe
D
1 x long pipe
E
2 x double female thread
F
connector
1 x single female thread
G
connector
1 x male thread connector
H
1 x white plastic cap
I
Place male thread connector
(H) through bottom malt
screen (B) and attach with
1 double female thread
connector (F).

Publicidad