DESCRIPTION
This self-priming portable utility pump is designed to be used as
a transfer pump for such applications as emptying water heaters,
livestock tanks, etc. Pump can also be used for an intermittent
pressure boost for applications such as washing cars, cleaning
driveways, etc. The motor is air cooled; it is not designed to operate
under water.
NOTE: This pump is not intended for permanent installation or long,
extended periods of continuous operation.
UNPACKING
After unpacking the utility pump, carefully inspect for any damage
that may have occurred during transit. Check for loose, missing or
damaged parts. If you need assistance, call our Customer Service
Department at 1-877-9RIDGID.
SAFETY GUIDELINES
To help recognize this information, observe the following signal
words/hazard classifications.
Danger indicates an imminently hazardous
situation which, if not avoided, WILL result in
death or serious injury.
Warning indicates a potentially hazardous
situation which, if not avoided, COULD result in
death or serious injury.
Caution indicates a potentially hazardous
situation which, if not avoided, MAY result in
minor or moderate injury.
Notice indicates important information, that if
not followed, may cause damage to equipment.
This is the safety alert symbol. It is used to alert you to potential bodily
injury hazards. Obey all safety messages that follow this symbol to avoid
possible harm.
NOTE: Information that requires special attention.
Motor
Single Phase - 115V, 60 Hz, 8,000 RPM
Motor
Series Wound (brush type) AC/DC Operation
Impeller
Thermoplastic
Motor Housing
Cast iron
Shaft and Volute
Buna-N
Seal
Maximum Fluid
120°F
Temperature
REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.
© 2017, Ridge Tool Company.
All manuals and user guides at all-guides.com
Self-Priming
Portable Utility Pump with Case
OPERATING INSTRUCTIONS & PARTS MANUAL
GENERAL SAFETY INFORMATION
GENERAL SAFETY
WILL result.
Do NOT use to pump flammable or explosive fluids such as
gasoline, fuel oil, kerosene, etc. Do NOT use in a flammable
and/or explosive atmosphere. Pump SHOULD only be used to
pump clear water. Personal injury and/or death WILL result.
Do NOT walk on wet areas until ALL power is turned off.
Failure to follow this warning WILL result in fatal electrical
shock.
1.
2.
3.
Personal injury and/or property damage COULD result.
4.
Specifications
Do not submerge motor or allow motor to be
exposed to water. Personal injury and/or death
Risk of electrical shock. ALL wiring must be
performed by a qualified electrician.
Read all instructions before operation.
Disconnect power and release all pressure within
the system before servicing any component.
Drain all liquids from system before servicing.
Secure the discharge line before starting the
pump. An unsecured discharge line MAY whip.
Periodically inspect pump and system components, checking
for weak and/or worn hoses. Insure all connections are secure.
Horsepower
1/2 HP
Inlet/Outlet Openings
3/4 inch NPT
Pump Housing
Cast iron
Motor Shaft
Cold rolled steel
Motor Bearings
Permanently lubricated
Rolling element bearings
PCRP
3213
05
-005 A 8/17

Publicidad

loading

Resumen de contenidos para RIDGID PCRP

  • Página 1 OPERATING INSTRUCTIONS & PARTS MANUAL READ, UNDERSTAND AND FOLLOW ALL INSTRUCTIONS IN THIS MANUAL - DO NOT DISCARD. Failure to follow these instructions could result in property damage, serious injury or death. PCRP DESCRIPTION GENERAL SAFETY INFORMATION This self-priming portable utility pump is designed to be used as...
  • Página 2 All manuals and user guides at all-guides.com Operating Instructions and Parts Manual GENERAL SAFETY INFORMATION (CONTINUED) INSTALLATION Pump motor is equipped with an automatic resetting thermal protector and MAY restart unexpectedly. Protector tripping is an indication of motor overheating ALWAYS disconnect power source before attempting to because of operating pump at low heads (low discharge restriction), operate, service, or maintain the pump.
  • Página 3 Replacement brushes may is over 10 feet or when suction line is over 10 feet long. be available from RIDGID. Call 1-877-9RIDGID to order. The inlet line may be galvanized pipe, plastic pipe, or reinforced Disconnect electrical cord from power supply.
  • Página 4 All manuals and user guides at all-guides.com Operating Instructions and Parts Manual SERVICE PART REPLACEMENT Make sure the pump is unplugged and cooled down before ROTOR ASSEMBLY THRUST WASHER disassembling the pump. Release any pressure from the pump then disconnect any hoses or plumbing, and drain the product.
  • Página 5 All manuals and user guides at all-guides.com PCRP TROUBLESHOOTING CHART Symptom Possible Cause(s) Corrective Action Pump will not start or run 1. Blown fuse 1. If blown, replace with proper sized fuse or reset breaker 2. Low line voltage 2. Contact an electrician 3.
  • Página 6 For Replacement Parts or Technical Assistance, Call 1-877-9RIDGID Please provide following information: Address parts correspondence to: - Model number RIDGID PUMPS - Serial number (if any) 101 Production Drive - Part description and number as shown in parts list Harrison, OH 45030 U.S.A.
  • Página 7 All manuals and user guides at all-guides.com PCRP NOTES...
  • Página 8 RIDGID water pumps are warranted to be free of material and workmanship defects for the one-year period from the date of purchase. This warranty is specific to this water pump and for the original owner and may not be transferred.
  • Página 9 No seguir estas instrucciones podría provocar daño a la unidad, lesiones graves o la muerte. No seguir estas instrucciones podría provocar daño a la unidad, lesiones graves o la muerte. Model # PCRP DESCRIPCIÓN INFORMACIONES GENERALES DE SEGURIDAD Las bombas portátiles de servicio con sistema de cebado automático SEGURIDAD GENERAL están diseñadas para usarse como bombas de desagüe para vaciar...
  • Página 10 All manuals and user guides at all-guides.com Manual de instrucciones de funcionamiento y piezas de repuesto INFORMACIONES GENERALES DE SEGURIDAD Tabla de las Longitudes de los Cordones de Extensión (CONTINUACION) Tamaño del Asegure la línea de descarga antes de dar alambre arranque a la bomba.
  • Página 11 Las escobillas no están cubiertas en __________________________________________________________ la garantía. Para ordenar escobillas de repuesto comuníquese con el distribuidor de bombas RIDGID más cercano a su domicilio. En EUA llame al 1-877-9RIDGID para ordenarlas. __________________________________________________________ 1.) Desconecte el cordón eléctrico del tomacorrientes.
  • Página 12 All manuals and user guides at all-guides.com Operating Instructions and Parts Manual REEMPLAZO DE PIEZAS DE REPUESTO Asegúrese de que la bomba esté desconectada y fría antes de ENSAMBLE DEL desarmarla. ARANDELA DE ROTOR EMPUJE Libere toda la presión de la bomba y luego desconecte las mangueras o tuberías, y drene el producto.
  • Página 13 All manuals and user guides at all-guides.com PCRP TABLA DE IDENTIFICACIÓN DE PROBLEMAS Síntoma Causa(s) Posible(s) Medida Correctiva La bomba no se 1. Un fusible quemado 1. Si está quemado, reemplácelo con un fusible enciende ni funciona adecuado o active el cortacircuito 2.
  • Página 14 Distribuidor Más Cercano a Su Domicilio Sirvase darnos la siguiente información: Dirija toda la correspondencia a: - Número del modelo RIDGID PUMPS - Código impreso 101 Production Drive - Descripción y número del repuesto según la lista de repuestos Harrison, OH 45030 U.S.A.
  • Página 15 All manuals and user guides at all-guides.com PCRP NOTAS Sp-15...
  • Página 16 Para obtener servicio para esta bomba de agua RIDGID debe enviarlo, con el flete pagado, a un centro de servicio autorizado para la reparación de bombas de agua RIDGID. Puede obtener la ubicación del centro de servicio más próximo llamando...