• For safety reasons, the Master PIN can only be
entered to access the programming mode. It
cannot be used as an entry code.
When two different codes or a wrong code
length is entered, all LEDs will flash three times,
indicating the code hasn't been saved. Try
again. [9] will remain lit.
6.3 MANAGE PIN CODE [1]
• Access programming mode (see 6. 1 )
A maximum of 100 different PIN codes can be
programmed (min. 4 - max. 8 digits).
• Press [1] and confirm with [#]
• [1] and [#] are both lit
• Enter a new PIN code and confirm with [#]
• In case of a new code, the code will need to be
repeated and confirmed with [#]
• The lights bellow button [1] and [2] are indicating
which relays are selected to be controled by this
code
• Pressing [1] or [2] will select (permanently on) or
de-select (flashing) the corresponding relay
• The selection is confirmed by pressing the [#] key
• You will return to the main menu of the
programming mode
When two different codes or a wrong code
length is entered, all keys will flash three times,
indicating the code setting hasn't been saved.
Try again. [1] will remain lit.
A code can be removed by de-selecting [1]
and [2] before confirmation
6.4 SET HOLD TIME RELAY 1 [3]
• Access programming mode (see 6. 1 )
• Press [3] and confirm with [#]
• [3] and [#] are both lit
• Enter the time (between 1 and 99 seconds) and
confirm with [#]
• A valid time is confirmed with a brief lighting of
all LEDs
• You will return to the main menu
Pulse mode : if the SlimStone-2 is used to
control automated systems, a pulse is required.
This mode can be activated by setting a time of
0 seconds. The pulse duration is 1000ms.
SlimStone-2
In case an invalid time is entered, all keys will
flash three times. Menu [3] remains activated.
The default time is set at 8 seconds.
6.5 SET HOLD TIME RELAY 2 [4]
• Access programming mode (see 6. 1 )
• Press [4] and confirm with [#]
• [4] and [#] are both lit
• Enter the time (between 1 and 99 seconds) and
confirm with [#]
• A valid time is confirmed with a brief lighting of
all LEDs
• You will return to the main menu
Pulse mode: if the SlimStone-2 is used to control
automated systems, a pulse is required. This
mode can be activated by setting a time of 0
seconds. The pulse duration is 1000ms.
In case an invalid time is entered, all keys will
flash three times. Menu [4] remains activated.
The default time is set at 8 seconds.
6.6 SET LIGHTING MODE [5]
• Access programming mode (see 6. 1 )
• Press [5] and confirm with [#]
• [5] and [#] are both lit
• Choose the mode in which you want the lighting
to work:
[1] Always on
[2] Auto-dim (default):
The brightness of the lighting is dimmed to
20% after 45 seconds inactivity. As soon as a
key is pressed, the lighting will be back at full
brightness for a minimum time of 45 seconds.
[3] Auto-off:
The lighting is switched off after 45 seconds
inactivity. As soon as a key is pressed, the
lighting is back on for a minimum time of 45
seconds.
• Press [1], [2] or [3] and confirm with [#]. When all
LEDs flash, your choice is saved
• You are back in the main menu of the
programming mode