Descargar Imprimir esta página

Bradley SN2003/AST4 Instrucciones De Montaje página 4

Publicidad

Idiomas disponibles

Idiomas disponibles

SN2003/AST4, SN2003/AST4-F, SN2023/AST4
Rough-In Locations for Wall Anchor Bracing
Dimensions are to determine reinforcement
locations. Use fixture as a template for precise
location of 3/8" anchors.
* Subtract 4" (102) from this dimension
for juvenile height model.
Rough-In Dimensions for Supplies
and Drain
Notes
Maximum flow rate required to washfountain is 1 .5 GPM . Size supply lines
accordingly .
Supplies from Below: Stub up 2-1/2" (64) .
Supplies from Above: Supplies must be located on centers of dimensions
shown to pass through washfountain shroud and sprayhead .
Drain through floor: Stub up 3" (76) .
Supplies from Below or Through Wall
Type A
Off-line vent
(P-Trap supplied by
Installer .)
2-3/4"
(70)
5"
(127)
C
C
L
4-1/2"
(114)
H
5"
(127)
When running supplies and drain through wall, use same horizontal measurements as shown in Top
View. Position openings above the finished floor, at the following dimensions (to center):
Drain: Standard Height: 19-1/4" (305)
Juvenile Height: 15-1/4" (387)
4
Type H
Centrally rising vent
(P-Trap furnished
with unit .)
Top View
2-3/4"
(70)
C
4-1/2"
(114)
4-1/2"
(114)
H
5"
(127)
8-3/4"
(222)
8/24/2020
Floor-Mounted
Units Only
Key
Type B
Centrally rising vent
(P-Trap furnished
with unit .)
2-3/4"
(70)
C L
7-9/16"
(192)
8-3/4"
(222)
Supplies: Standard Height: 12" (305)
Juvenile Height: 8" (203)
13-3/8"
(340)
10"
(254)
9"
(229)
8" Std
(203)
8-3/8" Juv
(213)
C L
1/2" Supply: Nominal Copper Tube
1/2" Supply Through Wall (Optional):
Nominal Copper Tube
1-1/2" NPT Drain
1-1/2" NPT Vent
Supplies from Above
Type O
Off-line vent
(P-Trap supplied by
Installer .)
Top View
2-3/4"
(70)
27/32"
(21)
C
C
L
H
27/32"
(21)
Bradley • 215-1072 Rev. L: ECO 20-00-015
Installation
(mm)
32-1/2"*
(826)
24-3/4"*
(629)
14-3/4"*
(203)
4-3/4"
(121)
27/32"
(21)
C
C
L
27/32"
H
(21)
7-9/16"
(192)

Publicidad

loading

Este manual también es adecuado para:

Sn2003/ast4-fSn2023/ast4