Technical Data - Trotec TDS 50 Manual Operativo

Generador eléctrico de aire caliente
Ocultar thumbs Ver también para TDS 50:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 12
MANUAL RESETTING
The appliance comes with a built
RESET
in security device that goes off au-
tomatically if the appliance should
happen to overheat.
If the security device should go off,
let the appliance cool down before looking for the
cause of the problem. Push the "RESET" button with a
small push rod to reset the appliance.
Should the problem persist, contact the Service Centre.
periOdic stOrage and cOntrOl
If the appliance is not used for a long period of time, it
should be cleaned before being put away. Store it in a
dry place and protect it from dust. When the appliance
is used again check to make sure that the electric
cable is not damaged. Should you have any doubts as
to the conditions of the appliance please contact the
Service Center.
The appliance should be checked at least once a year.
Only qualified personnel authorized by the manufac-
turer must carry out all repairs..
singling Out prOBlems
PROBLEM:
The appliance works
but does not heat.
The appliance does
not switch on.
Limited air flow
G
CAUSE:
Resistance is burnt out
Thermostat control is broken
Security device was set off
Faulty motor
Power supply interrupted
Air duct obstructed
Faulty motor
Operating manual – electric hOt air generatOr

technical data

Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4,5-9 kW
Absorbed current . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 A
Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400~V/50Hz
Air displacement . . . . . . . . . . . . . . . . . . . . . . . . 708 m
Thermostat range . . . . . . . . . . . . . . . . . . . . . . . . 0-40 °C
Size (mm) . . . . . . . . . . . . . . . . . . . . . . . . . . 320x380x515
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9,3 kg
SOLUTION:
Replace
Replace
Push "RESET"(
Replace
Unplug the appliance and check connection.
Clear the passage
Replace
/h
3
B - 2

Publicidad

Tabla de contenido
loading