INSTALLATION
Levelling
The supports should be positioned so as the operator forms an angle of 1° with regards
to the horizontal, remaining lower on the gate support side.
Mount the wall support
Respect the levels indicated in "Assembly
positions and levels" on page 31.
The screws (1) and plugs (2) are not
supplied. Use screws and plugs which are
suitable for the place of attachment and the
weight and effort of the operator.
Position the gate support
Respect the levels indicated in "Assembly
positions and levels" on page 31 and the slant
of the operator (see "Levelling" on page 32).
The screws (5) are not supplied. Use screws
which are suitable for the place of
attachment and the effort required.
32
Installation Manual
1 1
Mount the operator on the wall support
Introduce the shaft (3) and secure with the cap
(4), using a 6 mm Allen key.
Mount the operator on the gate support
Introduce the shaft (6) and secure with the cap
(7), using a 6 mm allen key.
1 1