Storage Conditions; Repair Operations; Troubleshooting; Blind Rivet Does Not Set - Gesipa TAURUS 1 Manual De Instrucciones

Remachadoras neumatico-hidraulicas para remaches ciegos
Ocultar thumbs Ver también para TAURUS 1:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TAURUS BA 1-4 Inhalt_prc-neu 2 04.08.11 15:45 Seite 15

8.4 Storage conditions

Keep tool in a dry, frost-proof area
9. Repair
In principle, warranty repairs should only
be carried out by the manufacturer.

10. Troubleshooting

10.1 Blind rivet does not set

Cause
– Jaws N° 15 dirty
– Jaws N° 15 worn
– Low air pressure
– Stroke too small

10.2 Spent mandrel is not evacuated

Cause
– Spent mandrel container full
– Wrong nosepiece in use
– Nosepiece worn
– Spent mandrel jammed in jaw housing
11. Warranty
This riveting tool has a 24 months warranty
from the date of delivery (to be proven by
invoice or delivery note). Damage caused by
wear, overload or improper handling is
excluded from the warranty.
When warranty expires, repairs should be
carried out by trained personnel. Failure to
correctly carry out setting instructions and
incorrect handling can lead to serious tool
defects. When in doubt, the tool should be
returned to the manufacturer.
Remedy
– Clean and lubricate (point 8.1)
– Change jaws (point 8.2)
– See air pressure requirement (point 4)
– Refill hydraulic fluid (point 8.3)
Remedy
– Empty spent mandrel container (point 7.5)
– Change according to table (Point 6)
– Change nosepiece
– Clean and oil jaws or change if worn
(point 8.2)
Damage caused by material or manufacturing
defects will be covered by the warranty and
will be repaired or replaced free of charge.
Claims can only be accepted if the complete
riveting tool (not dismantled) is returned to the
distributor, or to GESIP .
15

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Taurus 2Taurus 3Taurus 4

Tabla de contenido