INSTALLATION
1. Checking the installation distances
Before starting the installation it is essential to check the hinge and installation distances accord-
ing to the drawing above.
2. Installation of the door closer in the door leaf
The ATS tube door closer with front plate for lift doors with pivot hinges can be fitted at any
height in the door. It is attached to the door from the front with two countersunk head screws
M8.
3. Fixing of the articulation to the door frame
Turn the joint fork with a flat wrench size 14 until the groove of the joint fork is in a horizontal
position and the offset of the articulation points away from the pivot point.
Close the door slowly and, while doing this, introduce the threaded end M8x24 with the serrat-
ed washer in a ø 8.2 boring of the welding plate in the door frame. When the door is closed,
attach the spring washer and moderately tighten the M8 nut.
ATTENTION: In doing so the joint fork may not turn!
4. Setting up
Carefully open the door until you can hold the joint fork with a flat wrench size 14. Then tighten
the M8 nut with 20 Nm ± 2 Nm.
5. Adjusting
The final damping can be adjusted with the slotted screw in the front plate (see dimensioned
drawing).