SYSTEM
CREATION
MAGO Switch and MAGO Control Unit advanced settings menu
Parameter
Motor type
Motor for adjustable
shutter with
connector
Venetian blind
control mode
Specialisation
Upward travel
time
Downward travel
time
Position adjustment
time
Preferred position 1 0-100%
Preferred position 2 0-100%
Options
Standard (default)
Pulses
No (default)
Yes
CH Cherubini (default) Short pulse <1 sec: Impulsive
EU European
US United States
Rolling shutter
Awning
Screen
Venetian blind
Orientable shutter
0-240 seconds
(default 30)
0-240 seconds
(default 30)
10-100 tenths of a
second (default 10)
(default 25%)
(default 75%)
SYSTEM
CONFIGURATION
Description
For motors with a mechanical/electronic
limit switch with standard connection
(brown, black, blue). The outputs will
remain active throughout the travel (up/
down travel time).
For motors with white wire control. The
outputs are managed by pulses.
Mode 5
Mode 4
Long pulse >1 sec: Continuous motion
Short pulse <2 sec: Impulsive
Long pulse >2 sec: Continuous motion
Short pulse >0,5 sec: Impulsive
Long pulse <0,5 sec: Continuous motion
The specialisation is indicated during the
creation of the system and can be changed
from this menu.
Output activation time during the
motor raising movement
Output activation time during the
motor lowering movement
Total slat tilting time
Preferred intermediate position 1
Preferred intermediate position 2
37