Fine filter, polyester, area [m
Efficiency, fine filter, EN 60335-2-69, Class M
[%]
Filter area, HEPA filter [m
Efficiency, fine filter, EN 60335-2-69, Class H
[%]
Filter classification, EN 1822-1
Sound level [dB(A)]
Operation
Connection
Connect the machine to an electrical outlet with a voltage as per the machine's rating plate specifications. If using an extension
cord, it must be water-resistant.
Autostart
Connect the power tool to the electrical outlet on the machine. Set the switch to AUTO. The machine will then automatically start
when the tool is used. The machine turns off a few seconds after the connected tool is powered down. To manually start the
extractor, set the switch to MAN.
Filter cleaning:
The machine has a filter status indicator that lights up when the filter needs to be cleaned or replaced. The filters must be cleaned
1-2 times a day with continuous use .
Cleaning the filter:
During filter cleaning, the machine should be running and the hose removed from the suction pipe.
1. Press the connector sleeve against the black stop lug on the exhaust duct or against the floor in order to produce maximum
negative pressure in the cyclone.
Open and close the hatch on the side 3-6 times. Air flows into the machine and cleans the filter by creating a reverse pulse.
2. Turn off the machine and let the material fall down. Reconnect the suction pipe.
3. Start the machine.
2
]
2
]
DC 1800H, Art.nr. 94114-K
DC 1800H
230 V/16 A: 2200 W
1,5
99,9
0,85
99,995
HEPA H13
< 66
DC 1800H XL
230 V/16 A: 2200 W
1,5
99,9
0,85
99,995
HEPA H13
< 68
13