Parameter menu
Password (lock function)
After switching the lock function on, only the fixed
temperature keys can be operated on the solde-
ring station. All other settings are disabled until the
repair station is unlocked again.
Notice
If you want only one temperature value to be
selectable, the control keys fixed temperature
keys) must be set to the same temperature value.
Locking the soldering station
Set the desired three-digit locking code (between
001 and 999) using the UP / DOWN buttons.
Confirm the code with the Enter key.
The lock is active (the display shows a lock
symbol).
Single-channel display
To obtain more straightforward readings, the
display mode from can switched from 3-channel
display to 1-channel display.
If single-channel display is selected, the device
does not reset automatically to 3-channel display
after setting the temperature of a tool channel.
The display mode can be reset using ┌ 2 ┐.
Vacuum pre-feed
In order to prevent the pump from starting pre-
maturely or to ensure a defined soldering-joint
preheating time, it is possible to set an ON delay.
Vacuum run-on
To prevent the desoldering iron from becoming
clogged, it is possible to set a vacuum run-on time.
Menu access
Unlocking the soldering station
1. Call up the parameter menu. If the lock function
is active, the password menu item opens
automatically. Three stars (***) are shown on
the display.
2. Set the three-digit locking code using the UP /
DOWN buttons.
3. Confirm the code with the Enter key.
Forgotten code?
Please contact our Customer
Service: technical-service@
weller-tools.com
Menu access
Option
Description
OFF
Automatic reset to 3-channel display
(factory setting)
ON
No automatic reset to 3-channel
display
Menu access
Option
Description
0 sec
OFF: vacuum pre-feed function is
OFF (factory setting)
1-10 sec ON: vacuum pre-feed time, indivi-
dually
Menu access
Option
Description
0 sec
OFF: vacuum run-on function is OFF
(factory setting)
1-10 sec ON: vacuum run-on time, individually
adjustable