oil is a decreased tightening torque and an increased pulse frequency. (See "Test after ser-
vice")
After disassembly of pulse unit, fill with oil according to operation No. 1-5 below. Run
the machine in a vice for 10 seconds according to operation No. 6 below. Then continue
according to operation No. 7 -12. For best performance use Hydraulic Oil. 22 cST/40° C
(ISO VG22).
Oil : 22 cSt / 40˚C (ISO VG22)
1
2
3
6
2 Nm
2.5 mm
5
6 – 7 Bar
R
5 -10 Sec.