at least 65 cm, unless otherwise specified in the installation
instructions for the appliance or hob.
• The discharge of air must comply with local authorities
regulations.
• Ensure good air ventilation in the room where the appliance
is installed to avoid the backflow of gases into the room
from appliances burning gas or other fuels, including open
fires.
• Make sure that the ventilation openings are not blocked and
the air collected by the appliance is not conveyed into a
duct used to exhaust smoke and steam from other
appliances (central heating systems, thermosiphons, water-
heaters, etc.).
• When the appliance operates with other appliances the
maximum vacuum generated in the room should not exceed
0.04 mbar.
• Make sure not to cause damage to the mains cable.
Contact our Authorised Service Centre or an electrician to
change a damaged mains cable.
• If the appliance is connected directly to the power supply,
the electrical installation must be equipped with an isolating
device that allows to disconnect the appliance from the
mains at all poles. Complete disconnection must comply
with conditions specified in the overvoltage category III. The
means for disconnection must be incorporated in the fixed
wiring in accordance with the wiring rules.
• Do not flambé under the appliance.
• Do not use to exhaust hazardous or explosive materials and
vapours.
• Clean the appliance regularly with a soft cloth to prevent the
deterioration of the surface material.
• Do not use a steam cleaner, water spray, harsh abrasive
cleaners or sharp metal scrapers to clean the surface of the
appliance. Use only neutral detergents.
47