ALL ABOUT THE UV BULBS

UV Lamp replacement

Our sterilizer is equipped with two high quality Italian made UV lamps by OSRAM. The lamp has low mercury
content and ozone-free. Third lab test report has shown 99.9% bacteria killing when use as directed and with
the same equipped UV lamps. The life span of each UV lamp is approximately 6,000 hours according to the
manufacturer. If you think that a lamp needs replacement, please follow the instruction below. You can also visit
www.wabibaby.com to purchase replacement light lamps, OSRAM GMBH/HNS4W5G.
Uninstall
Always unplug the appliance before replacing the light bulbs.
With a good grip of the bulb, twist the bulb 45 degrees
downward. Pull to lower the entire bulb down to take it off the
socket.
Install
Caution: Do not touch the glass part of the UV lamp with bare
hands. Use cotton gloves. If you touch the glass, clean it with a lint
free cloth. Grease or residue on the UV lamp can potentially affect
the performance of the bulb.
To install the new lamp, line its prongs up with the slots in either
socket. Push the tube straight up into the sockets, and then rotate
it 45 degrees until you feel it locks into place. You can give the
lamp a gentle tug to ensure that it is firmly in place.
WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or
other reproductive harm. All Fluorescent bulbs including germicidal UV bulbs contain a small amount of mercury
sealed within the glass tubing. To minimize exposure to mercury vapor, EPA recommends that residents follow the
instructions below.
Actions to take to prevent broken bulbs:
Switch off and allow a working bulb to cool before handling.
Screw or unscrew the bulb by holding the plastic or ceramic base, not the glass tubing.
Never forcefully twist the glass tubing.
You can consider using a drop cloth (e.g. plastic sheet or beach towel) when changing the bulb should a
breakage occur. The drop cloth will help prevent mercury contamination of nearby surfaces and can be
bundled with the bulb debris for disposal.