Gallagher W-1 Weigh Scale User Guide
Installing the loadbars
1.
Select a weighing site that provides a solid, level and well drained surface.
2.
Ensure the loadbars and platform are well secured and clear of any
obstructions.
3.
Either bolt the loadbars to the concrete pad or locate them on studs set into
the concrete. It is important that the loadbars and platform sit flat without
any rocking or twisting to avoid weighing inaccuracies.
Note: It may be necessary to shim the loadbars or platform to ensure there
are no twisting pressures within the platform. Weights should be evenly
distributed over the top of the weigh bars.
4.
For Wired Loadbars: Connect the loadbar cables to the W-1.
For Wireless Loadbars: The W-1 must be within 8-10m of the loadbars.
Refer to the Gallagher Loadbars Instruction manual for further installation
information.
A beep will sound indicating a successful connection/ disconnection of the
loadbars.
WARNING – Do not weld the loadbars or any structure that they are
attached to. Loadbars contain sensitive electronic devices which will be
damaged by welding. Damage caused by welding will void warranty.
Position the W-1:
clear of the platform to ensure it
does not interfere with the flow
of animals during the weighing
cycle
within easy reach of the loadbar
leads if using wired loadbars
within easy reach of the operator
(for manual weighing)
5