Adapting todifferenttypes of gas
If theappliance is configured for a differenttype of gas than
that available, you have to replace the injectors with ones
corresponding to the type of gas to be used (see tables on
the preceding pages). The replacement will be made using
an adequate 7 mmkey after having lowered the burnersas
in thefollowing images. After replacing theinjector, regulate
the air to 1mm for natural gas and to the maximumif LPG.
Toadjust the minimum, after lighting the burner, remove the
knob and the gasket below and rotate the screw of the tap
(B - see page 12), which should be totally closed for
LPG and opened about 3/4 turn for natural gas, keeping
in mind that a flame lower than 3 mm may not even be
"perceived" by the thermocoupleof the tap. After regulating
the minimums,replace the gaskets and knobs.
1 -Unscrew the fixing screws of the burner.
FRONT
2 -Lower the burner and replace the injector.
BACK
BACK
FRONT