"Ubinas" - ref. 634 13 42
2 3 0 V
~
5 0 H z
6
B K
8
B U
T : Safety thermostat
V : Fans
Ph : Phase
N : Neutral
Figure 12 - Electrical wiring
2.7. Recommendations for installation
and insulation
For all the various installation configurations, the hearth
plate must be made from incombustible material. If the
walls of the chimney are made from combustible
material, the installation should be carried out as
follows (figure 8, page 8).
In the case of use of incombustible materials, we
recommend that an air space be left around the
appliance.
2.8. Electrical connexion
The electric installation must be carried out in
accordance with the regulation in force.
Electrical connections should not be made until all other
installation operations are completed (fixing, assembly,
etc...).
Complies with :
- Low tension Directive 73/23/CEE, under standard
NF-EN60335-1.
- Electromagnetic compatibility Diretive 89/336/CEE.
The fans electrical requirement is 230 V ~ 50Hz. Plug in
the power cable on a wall socket with a link to an earth
socket and protected by a 1 A fuse-wire.
Please note : When using a variator of speed
(optional), connect the fans on the variator (Use only
the FRANCO BELGE variator ref. V634 10 37).
Very important ! The power supply cable is resistant to
temperatures of 300°C. Ensure that the same type of
cable is used if it is replaced.
Technical manual "1250"
L
N
G N Y E
B N
B U
B K
8
BU : blue
BN : brown
BK : black
GNYE : green/yellow
Figure 9 - Preparing the insert fire
Figure 10 - Flue damper control
Figure 11 - Setting
2.9. Preparing the insert fire
Figure 9
When the chimney hearth hight is less than 544 mm :
-
Remove the glass door.
-
Remove the flue damper control and flue damper
(2 bolts).
-
Remove the flue collar (2 screws).
Installation instructions
Beam
protection
9