Descargar Imprimir esta página

Lorelli DAILY COMFORT Manual De Instrucciones página 7

Bomba de leche eléctrica

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 106
General description (Picture 1)
1. Cover - 1 pcs./2 pcs.* ; 2. Massage cushion - 1 pcs./2 pcs.* ; 3. Pump body - 1 pcs./2 pcs.* ;
4. Silicone diaphragm- 1 pcs./2 pcs.* ; 5. Cap - 1 pcs./2 pcs.* ; 6. Silicone tube - 1 pcs. ;
7. Valve - 1 pcs./2 pcs.* ; 8. Bottle - 1 pcs./2 pcs.*; 9. Cap & Ring & Teat - 1 pcs./2 pcs.*;
10. Motor unit - 1 pcs. ; 11. Adapter - 1 pcs. ;
12. T-shaped push-on tube connector - 1 pcs. (on double pump only, for expressing using two breast shields)
* - For parts which are marked with "*" - 1 pcs. for pump DAILY COMFORT, 2 pcs. - for DOUBLE pump DAILY
COMFORT.
Cleaning and sanitizing
The motor unit, the silicone tube, cap and the adapter do not require cleaning and sanitizing, as they do not come into contact with breast milk.
Clean and sanitize all other parts of the breast pump before first use. Also clean these parts after each subsequent use and sanitize them before
each subsequent use.
Caution! : Never put the motor unit or the adapter in water, in a dishwasher or in a sanitizer, as this causes permanent damage to these
parts.
1. Disassemble the breast pump completely. Also remove the valve. Be careful when you remove the valve and when you clean it. If it gets
damaged, your breast pump does not function properly. To remove the valve, gently pull at the ribbed tab on the side of the valve.
2. Clean all parts, except the motor unit, the silicone tube and cap and the
adapter, in the dishwasher (on the top rack only) or in hot water with some mild washing-up
liquid and then rinse them thoroughly. To clean the valve, rub it gently between your fingers in warm water with some washing-up liquid. Do not insert
objects into the valve, as this may cause damage.
Warning! - Do not use antibacterial or abrasive cleaning agents when you are cleaning.
Note: Make sure you have cleaned and sanitized the appropriate parts of the breast pump.
Wash your hands thoroughly before you handle the cleaned parts.
Warning! - Be careful, the cleaned parts may still be hot. Only start assembling the breast pump when cleaned parts have cooled down.
LCD DISPLAY & KEY FUNCTION ( Picture 2 )
A.
On-Off Key
; B.
Mode Key
Е2. Normal pumping mode; Е3. Deep pumping mode
BATTERY OPERATION ( Picture 2 )
WARNING!!! Before first use, fully charge the battery for 8 hours uninterrupted! Once the pupm is started, the digits on the display will show
the remaining battery life until the battery runs out, and then the selected vacuum level will be displayed. Charging indicator will apear while charging
and fully charged indicator will appear once the battery full. Attention: Battery can not be charged over 24 hours.
ASSEMBLY OF THE BREAST PUMP
1. Insert the valve into the pump body from underneath. Push the valve in as far as possible.( Picture 3 )
2. Screw the pump body clockwise onto the bottle until it is securely fixed.(Picture 4)
3. Insert the silicone diaphragm into the pump body from above. Make sure it fits securely around the rim by pressing down with your fingers to ensure a
perfect seal. (Picture 5 )
4. Attach the silicone tube and cap onto the diaphragm. Push down the cap until it is securely in place.
(Picture 6)
5. Insert the massage cushion into the funnel-shaped section of the pump body. Push in the inner part of the cushion as far as possible and make sure that it
is perfectly sealed all around the rim of the pump body. Press in between the petals to remove any trapped air. Warning! Always use the breast pump with a
cushion.
Insert the adapter into the wall socket and insert the plug at the other end into the motor unit. (Picture 7).
6. For single breast pumping through one pump body, please insert the free end of the silicone tube which is intended for the second pump body, into the T-
Shaped plastic element marked with arrow as is shown on
(Picture 8)
7. For double breast pumping each of the silicone tubes shall be inserted into the relevant pump body as is shown on picture 9.
Cleaning and sanitizing FEEDING BOTTLE 180ml
- Before first use, disassemble and clean the product and then put the components in boiling water for 5 minutes. This ensures hygiene.
- During disinfection with boiling water, do not allow the bottle or other parts to touch the side of the pot. This may cause irreparable deformation or damage
to the product for which Lorelli is not responsible.
-Clean carefully before each subsequent use to ensure hygiene.
- Wash all parts with warm water and delicate detergent. Always rinse all parts thoroughly after each wash.
- Wash thoroughly and rinse all parts with clean water, including areas that may not be visible but through which the food has passed, to remove food
debris. Make sure there is no liquid left in the pacifier.
- Do not place in a microwave oven. Do not heat the product in traditional ovens, on hot plates or open flames.
- Avoid the use of sharp or abrasive materials, as this may damage the product.
- Do not clean or allow the product to come into contact with solvents or aggressive chemicals. This may damage the product.
- If you use bottle brushes, be careful not to damage the most delicate parts of the product.
- After cleaning the product, dry all parts thoroughly and store in a clean and dry place without direct sunlight and away from heat sources.
- Do not leave the pacifier in direct sunlight or heat or leave it in a disinfectant ("sterilizing solution") for longer than recommended, as this may damage the
pacifier.Note: Be sure to clean and disinfect the relevant parts of the breast pump. Wash your hands thoroughly before working on clean parts!
PREPARING FOR USE
; C.
Increase Vacuum
; D.
Reduce Vacuum
FEEDING BOTTLE 180ml
PARTS
E1. Massage mode;
7

Publicidad

loading

Productos relacionados para Lorelli DAILY COMFORT

Este manual también es adecuado para:

Doble daily comfort